Laserfiche WebLink
ISM-4080 and ISM-4081 Specifications <br /> For Use With: <br /> • 99 LD-2000, 99 LD-3000 Mechanical Line Leak Detectors. <br /> Leak Detector Sensor Housing, <br /> Part # ISM-4101 and Part # ISM-4102 are constructed of: <br /> • 6061 T-6 Aluminum <br /> • All Aluminum is Hard Anodized <br /> • Viton 0-rings are compatible with: Gasoline, Methanol and Ethanol (all blends through 100%), <br /> MTBE through 15% concentrations, #1 or#2 Diesel, Kerosene, Jet A, JP-4,AV Gas, and Biodiesel <br /> • Switch is approved for total immersion in above liquids. <br /> Leak Detector Sensor Housing Dimension: <br /> • Height: 2 318", 61 mm <br /> ISM Controller Housing Dimensions: <br /> • Length: 3112", 89mm Width: 4118", 105mm Depth: 2 114", 57mm <br /> Input Voltage: <br /> 115 Vac, 50160 Hz, single phase, control circuit current 40 ma <br /> • 230 Vac, 50160 Hz, single phase, control circuit current 20 ma <br /> • Input voltage is selectable by choice of external wiring <br /> Authorization Input Voltage Range: <br /> • 60 - 240 Vac <br /> Output Relay Rating: <br /> • Ready Relay for Solenoid Valve Control 8 amp, 1251250 Vac: 5 amp, 30 Vdc <br /> • Exterc <br /> For use with intrinsically safe input, an isolation relay is needed. <br /> Sensor Input: <br /> • Piston Switch may share the same wire pair as a single pole, normally closed, sump sensor compatible with <br /> intrinsically safe circuitry. Intrinsically safe voltage and current supplied from the ISM-408014081 to the Piston <br /> Switch and Sump Sensor Circuits, for hazardous locations, Class 1, Group D. Wiring for sensors shall not be in <br /> the same conduit as high voltage wiring, nor installed in any way as to allow sensor wiring to current that is not <br /> supplied by an intrinsically safe source. <br /> Tank Monitor Disable Input Voltage Range: <br /> • AC Type: 60-240 Vac - Typical AC Voltage: 115 Vac @ 10 ma <br /> • DC Type: 5-24 Vdc - Typical DC Voltage: 24 Vdc @ 1 ma <br /> Selectable Repressurization Delay, based upon Line Resiliency,Values in Minutes: <br /> • 02, 05, 10, 15, 30, 45, 60, 75, 90 <br /> Selectable Duration (submersible run time),Values in Minutes: <br /> • 00 (none), 01, 02, 03, 04, 05, 06, 07, 08, 09, 10 <br /> ISM-4080 and ISM-4081 Controller: CSA Approval Pending <br /> Vaporless Manufacturing, Inc. Toll Free: 1-800-367-0185 <br /> VM1 8700 East Long Mesa Drive Phone: (928) 775-5191 <br /> Prescott Valley, Arizona 86314 Fax: (928) 775-5309 <br /> 02JOB Web Site: www.vaporiess.com 9 Email vmi@vaporiess.com <br />