My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ALPINE
>
1235
>
2300 - Underground Storage Tank Program
>
PR0231512
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2021 10:26:30 PM
Creation date
11/2/2018 9:28:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231512
PE
2381
FACILITY_ID
FA0004512
FACILITY_NAME
MAJOR STATIONS
STREET_NUMBER
1235
Direction
E
STREET_NAME
ALPINE
STREET_TYPE
AVE
City
STOCKTON
Zip
95204
APN
11533055
CURRENT_STATUS
02
SITE_LOCATION
1235 E ALPINE AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\ALPINE\1235\PR0231512\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
12/5/2011 8:00:00 AM
QuestysRecordID
100073
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORN01 WATER RESOURCES CONTP BOARD <br /> FORM `B': UNDVhGROUND STORAGE <br /> ILNFORMAT TANK. <br /> A <br /> OMPLETE <br /> TANK TANK PERMIT APPLICATION <br /> CA SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH G <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWALPERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 P MANENTLY CLOSED TANK 1 <br /> ONE ITEM ❑2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE TANK REMOVED 0 <br /> 3 FARM TANK-YES <br /> ❑ NO IV <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: - N <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY W <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> 44 I1. TANK CONTENTS IF(A.1),18 MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL [—] 2 P ROLEUM B. C. E] 1 UNLEADED ❑2 LEADED ❑3 DIESEL <br /> ❑3 CHEMICAL PRODUCT 4 OIL ❑ 1 P UCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ SO EMPTY ❑ 95 UNKNOWN UKWASTE ❑7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF r �� O r / C.A.S.#: ©� <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# �l <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,A D <br /> A TYPE OF ❑ 1DOUBLE WALLED F-13 SINGLE WALLED WITH EXTERIOR LINER E] 95 UNKNOWN <br /> Z SIN <br /> SYSTEM g1GLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> STEEL/IRON 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑4 STEEL CIAO W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK ❑5 CONCRETE E]6 POLYVINYLCHLORIDE ❑7 ALUMINUM F-18100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 111 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> ❑ 1 RUBBERLINED ❑2 ALKYDUNING ❑3 EPDXY LINING ❑ 4 PHE LINING <br /> LINING ❑ <br /> C. INTERIOR <br /> 5 GLASS LINING F-16 UNUNED UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WRH 100%METHANGL? ❑YES ❑NO ❑99 OTHER <br /> D.CORROSION ❑ I POLYETHLENEWRAP ❑2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑ 91 NONENKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE <ujrRAVlTY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P 4 6 PRECISION TESTING P S 7 PRESSURE TESTING It P 8 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MOLAR) 2.ESTIMATED QUANTITY OF 1 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN INERT MATERIAL? ❑YES [-] NO <br /> GALLONS <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. '.. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> 17-/ O <br /> CURRENT LO AGENCY FACILITY ID APPROVED BY NAME Dµ�j PHONE WITH AREA CODE <br /> PERMIT NUMBER j PERMIT APPROVAL DATE PERMIT XPIRATIOND�ATTEE. <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT X BY: <br /> FORM B(6-29-BB) THIS FORM MUST BE ACCO MPANIL,_oA FACILITY/SITE APPLICATION, FORM'A',UNLESS A'L'ORRENT FORMA' HAS BEEN FILED / <br /> DATA PROCESSING COPY <br />