Laserfiche WebLink
MINIMUM VERIFICATION LABORATORY ANALYSIS <br />TANK <br />TANK <br />TPII-O <br />TPH-D <br />BTX & E <br />CL IIC <br />TOTAL <br />EDB <br />METALS <br />PCD <br /># <br />CONTENTS <br />8015 <br />8015 <br />8020 <br />8010 <br />LEAD <br />Spectrometry 7000. Metals: Cadmium, Chromium 111 and VI, Lead, Zinc and Nickel. <br />]CAP/ <br />8270 <br />Method 3050 <br />Acid digestion <br />8260 <br />8260 <br />8260 <br />8240 <br />7420 <br />8240 <br />AES or <br />8080 <br />7421 <br />AA <br />90 <br />LEADED <br />OAS <br />X <br />X <br />X <br />X <br />UNL GAS <br />X <br />X <br />DIESEL <br />X <br />X <br />KEROSENE <br />X <br />X <br />UNK FUEL <br />X <br />X <br />X <br />X <br />X <br />PROD. OIL <br />X <br />X <br />CIILOR. <br />SOLVENTS <br />X <br />X <br />NONCHLOR <br />SOLVEMS <br />X <br />X <br />X <br />W ASTE1 <br />USED OIL <br />X <br />X <br />X <br />X <br />X <br />X <br />All analyses methods are designated EPA methods described In EPA SW 846, Third Edition. Those methods not found <br />In SW 846, are specifically noted below. Refer to the "SWRCB LUFT Field Manual", Appendix A-20, Table 3-5 for <br />detection limits of motor vehicle fuels (gasoline and diesel). Refer to 1-2-3 "Regional Board Staff Recommendations for <br />Initial Evaluation and Investigation of USTs' for the waste and motor oil detection limits. <br />Detection Limits that remain below the MCI, STLC or Allowable Limit of the contaminant In question will be accepted, <br />however laboratory shall utilize the most conservative method. <br />LABORATORY ANALYSES TERMINOLOGY: <br />T 14-O <br />Total Petroleum Hydrocarbon, Gasoline, GC/FID (5030) 8015 mod or GC/MS 8260 <br />Tptl-D <br />Total Petroleum Hydrocarbon, Diesel, GC/FID (3550), 8015 mod or OC/MS 8260 <br />BTX & E <br />Benzene, Toluene, Xylene & Ethyl Benzene, OCRID 8020 or ODMS 8260 <br />CL FIC <br />Chlorinated Hydrocarbon, OC/IISD 8010, OC/MS 8240 <br />TOTAL LEAD <br />Total lead, AA 7420, AA 7421 or ICP -AES 6010 <br />EDB <br />Ethylene dibromide (DIIS-AB 1803), OCIMS 8240 (DFIS-LUPI) <br />GC -FID <br />Gas Chromatography, Flame Ionization Detection <br />ICAP or AA <br />Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption <br />Spectrometry 7000. Metals: Cadmium, Chromium 111 and VI, Lead, Zinc and Nickel. <br />PCD <br />Polychlorinated Biphenyls, GAMS 8270 or 8080 <br />Method 3050 <br />Acid digestion <br />Method 3540 <br />Soxhlel sample preparation <br />Method 3550 <br />Sonication sample preparation, extraction method <br />Method 5030 <br />Purge and trap sample preparation <br />QA/QC <br />Quality Assurance/Quality Control <br />Notes: To avoid false positive detection of benzene, benzene -free solvents are to be used. Fused capillary columns are <br />preferred to packed columns; a packed column may be used as a "first cut" with "dirty" samples or once the hydrocarbons <br />have been characterized and proper QA/AC is followed. <br />For Drinking water sources, EPA recommends that the 500 series for volatile organics be used in preference to the 600 <br />series because the detection limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal <br />contamination may require further analysis. PHS-EIID recommends holding these samples until disposal is Indicated. <br />Ell 23 048 (Revised 7/10/92) Page 8 <br />