My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
COMPLIANCE INFO_2013 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2023 2:07:49 PM
Creation date
11/4/2018 2:28:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2016
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DANIELS\2440\PR0527629\COMPLIANCE INFO 2013 - 2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
461
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 SAN JOAQUIN COUNTY 9 <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.si-ov.ora/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Facility Inspection <br />Name: (Costco Wholesale #1031 Address: 2440 Daniels, Manteca Date. Aug 19, 2014 <br />VIOLATIONS <br /># C1 C2 M I Code Section HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation M = Minor violation <br />Non -Pressurized Piping (continued) <br />742 'CCR 2643(e) Biennial tightness test of gravity piping not performed (pre -January 1 1984) (M1 <br />703L I I I CCR 2643(d) Triennial line test for conventional suction piping_ not performed (pre -January 1. 198.4) (Mi <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report' for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />This is a report of the Routine and Monitoring System Certification inspection conducted at the <br />referenced facility by San Joaquin County Environmental Health Department (EHD). The following are <br />Class II Repeat violations: 305, 406 <br />305. The sensor in the 91 -octane fill sump was found to be defective when tested by technician as it <br />would not come out of sensor -out alarm (first discovered by contractor Elite IV, who reprogrammed it to <br />bypass positive shutdown on August 18, 2014.) All monitoring shall be maintained to activate an audible <br />and visual alarm or stop the flow of product at the dispenser when it detects a leak. Correct immediately <br />by having a properly licensed, trained, and certified contractor replace the failed component with a <br />functional component (LG 113-x listed, if applicable) and obtain a permit within one business day from <br />the EHD. If the failed component can't be replaced immediately, there is a possibility that the UST <br />system may be red tagged to prevent fuel inputs. <br />The sensor was replaced on site by Alltech Petro, a licensed contractor company. Violation has been <br />corrected. <br />406. The Dispenser 9110 annular sensor failed when tested. The sensors monitoring the liquid level in <br />the interstitial space shall be maintained so that a breach in the primary or secondary containment is <br />detected before the hazardous substance is released into the environment. Correct immediately by <br />having a properly licensed, trained, and certified contractor replace the failed component with a <br />functional component (LG 113-x listed, if applicable) and obtain a permit within one business day from <br />the EHD. If the failed component can't be replaced immediately, there is a possibility that the UST <br />system may be red tagged to prevent fuel inputs. <br />The sensor was replaced on site by Alltech Petro, a licensed contractor company. Violation has been <br />corrected. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />ERD 239' Rg104119/12,,�_ /14 Page -3 I/ UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.