Laserfiche WebLink
Ll <br />• <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s ov.or /ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facilely Costco Wholesale #1031 Facility 2440 Danit?Is Street Manteca Inspection <br />Name: Address: r Date: Aug 21, 2013 <br />Facility <br />Contact: Julian Ochoa rltle: fuel station manager ftlr_2860 <br />Inspection <br />Type: XRoutine XMonitoring System Certification L Installation I . Complaint — ID#: Other: <br />(Authority HSC 25289) <br />Consentfor: XInspection ]Sampling XPhotos Granted by: Julian Ochoa Title: fuel station manager <br />Monitoring Veeder-Root TLS -350 Piping X pressurized ❑ Suction ❑ Gravi Overfill I Mechanical <br />Panel: System: Gravity Prevention: XAudible/visual <br />UST 1 2 3 4 <br />Product - - - - - - - -87A _-.- - - - - -- ------------- <br />- 87B - - - - - - - -91-octane -------------- <br />- - - - - —Lubrizol--- ............ <br />---- ------ <br />Operator: Freddy Barrita Soriano e: 050914 <br />Operator: Violations: ] M1 -Release Detection C M2 -Release Prevention I I M3 —Both <br />On Site Service ICC Exp. Manufacturers <br />Technician: Isaac J. Anderson Date: 062214 Training VMI 031915 VR Lev4 082114 <br />%!illi A r1r%k10 <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSG = California Health and Safety Code; CCR = California Code of Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />File Review <br />101 HSC 25284 No permit to operate <br />102 HSC 25404.5 Annual operating fees not paid <br />103 HSC 25284(x)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 CCR 2632(b) Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 CCR 2637 Secondary containment; (a) test not performed; (e) test report not submitted within 30 days; (f) test notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />109 CCR 2638 (e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 HSC 25291(f) Annual line leak detector test not performed (M1) <br />Ill HSC 25284.2 Annual spill containment testing not performed <br />112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />113 CCR 2715(a) Failed to inform the EHD of achange of designated operator within 30 days <br />114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br />115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />ermit conditions <br />116 HSC 25292.5 Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 CCR 2661 Permit to repair UST system not obtained <br />118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) Permit to temporarily close UST system not obtained <br />120 HSC 25298(c) Permit to close UST system not obtained <br />On Site Records <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/2 years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />201 <br />CCR 2712(b) <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />e ui ment, round water elevations, or other test results; 6 results of invento readings and reconciliations <br />202 <br />CCR 2712(i) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />203 <br />CCR 2650 <br />was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Thuy Tran (209) 468-8257 <br />EHD 23-02 Rev 04/19/12 <br />Page 1 <br />Title. <br />UST INSPECTION REPORT <br />