SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sogov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Costco Wholesale #1031 Facility 2440 Daniels Street, Manteca Inspection Aug21 2013 <br />Name: Address: Date: <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />Routine UST Inspection, Annual Monitoring System Certification & SR0067678 <br />Amended UST report on September 3, 2013 from August 21, 2013 inspection. <br />Violations 313 & 406 corrected on site. <br />313. The 87-B spill container failed when tested. The drain valve had to be replaced. All spill containers <br />shall have a minimum capacity of five gallons and be capable of containing a spill or overfill until it is <br />detected or cleaned up. The spill container's drain valve was replaced and retested during the <br />inspection. <br />406. The 87A product - SJ smart sensor failed when tested. The interstitial space of the UST system <br />shall be maintained, as designed, under constant vacuum such that a breach in the primary or <br />secondary containment is detected before the hazardous substance is released into the environment. <br />Correct immediately by having a properly licensed, trained, and certified contractor replace the failed <br />component with a functional component (LG 113-x listed, if applicable) and obtain a permit within one <br />business day from the EHD. If the failed component can't be replaced immediately, there is a possibility <br />that the 87A UST system may be red tagged by the to prevent fuel inputs EHD. <br />- Corrected on site. Technician replaced the failed component, retested & passed. Displayed no vacuum <br />& high liquid alarms. <br />Notes; <br />-Reviewed briefly over HMBP hardcopy submitted by 3E Company for Costco Wholesale. Site Map 2 of <br />2 & HMBP will need to add 1500 gallon Underground Storage Tank Lubrizol Additive to inventory & <br />location. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />inspector. Received By: + Title: <br />t <br />UST INSPECTION REPORT <br />EH J 23-02 Kev 04119111 <br />rage 3 <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and SofEq Code; CPR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M - Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 <br />Other: <br />See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />Routine UST Inspection, Annual Monitoring System Certification & SR0067678 <br />Amended UST report on September 3, 2013 from August 21, 2013 inspection. <br />Violations 313 & 406 corrected on site. <br />313. The 87-B spill container failed when tested. The drain valve had to be replaced. All spill containers <br />shall have a minimum capacity of five gallons and be capable of containing a spill or overfill until it is <br />detected or cleaned up. The spill container's drain valve was replaced and retested during the <br />inspection. <br />406. The 87A product - SJ smart sensor failed when tested. The interstitial space of the UST system <br />shall be maintained, as designed, under constant vacuum such that a breach in the primary or <br />secondary containment is detected before the hazardous substance is released into the environment. <br />Correct immediately by having a properly licensed, trained, and certified contractor replace the failed <br />component with a functional component (LG 113-x listed, if applicable) and obtain a permit within one <br />business day from the EHD. If the failed component can't be replaced immediately, there is a possibility <br />that the 87A UST system may be red tagged by the to prevent fuel inputs EHD. <br />- Corrected on site. Technician replaced the failed component, retested & passed. Displayed no vacuum <br />& high liquid alarms. <br />Notes; <br />-Reviewed briefly over HMBP hardcopy submitted by 3E Company for Costco Wholesale. Site Map 2 of <br />2 & HMBP will need to add 1500 gallon Underground Storage Tank Lubrizol Additive to inventory & <br />location. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />inspector. Received By: + Title: <br />t <br />UST INSPECTION REPORT <br />EH J 23-02 Kev 04119111 <br />rage 3 <br />