0 <br />Optional Select Switch Settings <br />10. To make changes to the configuration switches <br />SW3 and SW6 (See Figure 4), make sure power <br />supply is locked and tagged out, then remove <br />the two screws from the plastic shield covering <br />the User interface board. Set all DIP switches as <br />desired per the details below. <br />SW3 Pole 1 <br />ON for Mechanical Leak Detectors (factory <br />setting) <br />OFF For Some Electronic Line Leak Detection <br />systems. Required setting for Veeder Root PLLD <br />SW3 Pole 2 <br />ON for Gasoline (factory setting) <br />OFF for Diesel product <br />Note: Because gasoline has a different specific gravity <br />than diesel fuel, the correct setting of Pole 2 is <br />important to ensure that the MagVFC regulates <br />pressure at the desired level. <br />SW3 Pole 3 <br />ON for Master controller (See Master Slave <br />Control Connections for details) <br />OFF for Stand-alone operation or Slave <br />configuration (factory setting) <br />SW3 Poles 4 and 5 (Pipe Compensation) <br />See Calibration Section of this Manual for details <br />in setting these switches (default is ON, ON) <br />SW3 Pole 6 <br />ON when using PMAVS4 motor <br />OFF when using PMAVS2 motor (factory setting) <br />Note: Incorrect setting can cause the MagVFC to <br />give false indications of SC (short circuit) or UL <br />(underload). Set SW3 Pole 6 properly to horsepower <br />of pump connected. <br />SW3 Pole 7 <br />ON for Automatic reset of "Under Load" fault. <br />An empty tank will cause an Under load fault. <br />The MagVFC will automatically reset when the <br />condition is corrected. <br />OFF must push Reset button to clear the "Under <br />Load" fault (factory setting) <br />Note: Not functional in IST-VFC Compatibility Mode, leave <br />in OFF position. <br />SW3 Pole 8 (for multiple MagVFC controllers working <br />together) <br />See Alternating Circuit Control section for <br />details (default is OFF) <br />Note: Not functional in IST-VFC Compatibility Mode, set <br />with SW2 Pole 5 per Table 1A. <br />SW6 Pole 9 <br />See Troubleshooting section for details of the Extended <br />Run Alarm <br />ON Will disable the Extended Run Alarm <br />condition <br />OFF The Extended Run Alarm is active <br />(factory setting) <br />Note: Not functional in IST-VFC Compatibility Mode, leave <br />in OFF position. <br />SW6 Pole 2 (For Master -Slave and Alternating Circuit <br />configurations ONLY) - <br />See Master -Slave Fault Shutdown Control <br />section for details of this switch (default is OFF) <br />Note: Not functional in IST-VFC Compatibility Mode, set <br />with SW2 Pole 5 per Table 1A. <br />SW6 Pole 3 <br />ON for IST-VFC Compatibility Mode, unit will <br />then ONLY communicate with rev 1.5 software <br />IST-VFCs in Master -Slave configurations (not <br />for use in communicating Master -Slave with <br />other MagVFCs) <br />OFF native MagVFC Master -Slave <br />communication (factory setting) <br />Note: Available in MagVFC software versions 1.18 and <br />higher only. <br />SW6 Pole 4 <br />ON When the alternating circuit configuration is <br />used this will alternate submersibles every 30 <br />minutes when a hook signal is continuous. This <br />option is used to assist in keeping tanks balanced <br />at busy sites. <br />OFF Available in MagVFC software versions 1.22 <br />or higher only. <br />SW6 Pole 5 (Slave turn off) <br />ON When the MagVFC is configured for Master/ <br />Slave operation with 2 ETPs running, when <br />product demand decreases to the point that a <br />single submersible can meet the needed flow, <br />the slave will turn off in order to conserve energy. <br />Off the slave turnoff option is not enabled <br />and standard Master/Slave operation will be <br />performed. The slave will turn off only when the <br />hook signal goes low and the controllers go idle. <br />Note: Available in MagVFC software versions 1.23 or <br />higher only. <br />SW6 Poles 6 - 8 <br />These switches are not used. Leave them in <br />the OFF position. <br />Note: MagVFC may operate in an unpredictable manner if any <br />of the switches, SW6 Poles 6-8, are in the ON position. <br />7 <br />