Ll <br />Facility Name: Costco # 1003 Woodland (Page 2) <br />D. Results of Testing/Servicing <br />Complete the following checklist: <br />Is <br />Software Version Installed: 328.03 <br />® Yes <br />El No* <br />Is the audible alarm o erational? Deafening? Outside Alarm <br />® Yes <br />❑ No* <br />Is the visual alarm operational? <br />❑ Yes <br />❑ No* <br />Is the print function operational? <br />® Yes <br />❑ No* <br />Were all sensors visually ins ected, functionally tested, and confirmed operational? <br />❑ Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />® Yes <br />No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />❑ N/A <br />operational? <br />TT -Yes <br />71 No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />❑ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shutdown? (Check all that apply) ® Sump Sensors, ® Dispenser Containment Sensors. <br />Did you confirm positive shutdown due to leaks and sensor failure/disconnection? ❑ Yes; ❑ No. <br />E Emergency Shut Down (ESD) was tested and found to be working at each station. <br />23 Yes <br />El No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device, is the overfill <br />❑ N/A <br />warning alarm visible and audible at the tank till point(s) and operating properly? At what percent of tank <br />ca acity does the alarm trigger? 90% <br />❑ Yes* <br />❑ No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes* <br />❑ No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product ❑ Water; ❑ Brine. If yes, describe causes in Section E, below. <br />® Yes <br />❑ No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />El Yes <br />® No* <br />Is all monitoring equipment oerational per manufacturer's specifications? <br />E. Comments: The only issue that was left unresolved was a bad interstitial sensor surrounding the 7&8 <br />UDC. Elite 1V is scheduled to return tomorrow and will pull permit and arrange for recertification of <br />that sensor. <br />