EQXX.MH 11766 - Control, Mitoring and Auxiliary Equipment � Page 3 of 4
<br /> 6
<br /> through-037,inclusive,with up to eight probes Form No. 84739 followed by 0 or 1,followed by 0, 1, 2, 3,4,5,6 or 7,followed by 00 to 17
<br /> inclusive or Form No, 84639 followed by 0 to 9,followed by 0 to 9,followed by 00 to 99,and up to 21 sensors, Form Nos. 794380 Followed by-
<br /> 301,-302, -322,-352, -401, -404,-407, -409,-420,-460, -621, -622,-624, -700, May be provided with overfill alarm Form No. 790091-001 with
<br /> or without acknowledgement switch Form No.790095-001.
<br /> Liquid level gauge/leak detection system,designated TLS-450.Associated Apparatus,non-hazardous location,liquid level gauge/leak
<br /> detector control unit,Form No. 8600,followed by 90,followed by 1 followed by 00, provides intrinsically circuits for use in Class I, Div. 1,Group D,
<br /> may be used with up to 16 intrinsically safe probes/sensors per USM Module when installed in accordance with Control Drawing 331940-008.
<br /> Suitable Intrinsically Safe Devices for use in C,Class I,Division 1,Group D are 2to 1 Sensor Input Box, Form No. 857390-102 only for use with
<br /> Sump, Position Sensitive and Hydrostatic Sensors, Form Nos. 794380,Followed by-208,-209,-301, -304, -323;or Magnetostrictive probes,Form
<br /> No.84639,followed by 0 to 9,followed by 0 to 9,followed by 00 to 99 or Form No. 85639,followed by 0 or 1,followed by 0 to 9,followed by 00 to
<br /> 99,or Form No.857080,or Form No.846291,followed by-100 through -199 or ISD Flow Meter Form No. 331847-001,331847-002, 332374-001
<br /> or 332374-002,or ISD Pressure Sensor Form No.330020-515 or 330020-630 or Digital pressure line leak, Form No. 332681-XXX; or
<br /> Discriminating dispenser pan,containment pump, interstitial sump, hydrostatic and position sensitive sensors,Form No.794380 followed by-208,
<br /> -209,-301,-302,-303-304, -322,-323, -343,-344,-345, -352,-430 or Form Nos.794390,followed by -401, -404, -407,-409, -420,-449,-
<br /> 460; or CSTP Liquid Switch,UL Listed Veeder-Root Submersible Pump Basic Models PC or PAGC; or Vapor sensor, Form No.794390-700 or Solid
<br /> state discriminating sensors,Form No.794380,Followed by-320, -350,-360,-361,-362; or Solid state dispenser pan and containment sump
<br /> sensors, Form No.794380,Followed by -321,-351; or Ground water sensors, Form No. 794380,followed by-621,-622, -624; or The control unit
<br /> may also be provided with the following equipment for use in non-hazardous locations: Overfill alarm,Form No.790091-00,with or without an
<br /> acknowledgement switch Form No.790095-001,or I/O Module,Form No.865090-100,up to Four provided,or USM Modules,Form No.865090-
<br /> 200,up to four provided,module provides intrinsically safe circuits for combinations described above,or Communication Modules,Form Nos.
<br /> 865090-301,-302,-303, -304, -330,-331,-332,-333,-339,-340, -341,or-401; may be used with peripheral equipment as specified in the
<br /> installation instructions.
<br /> Wireless line leak detectors,Form Nos. 849490-001, -002,-003, -004 or-005.
<br /> Liquid-level gauge accessory,designated TLS-RF,consisting of:
<br /> Associated Apparatus,Non-Hazardous Location,Control unit Model TLS-RF,Form No. 332242-001,-002 for use in non-hazardous locations,
<br /> provides intrinsically safe outputs for use in Class 1,Group D when used and installed as specified in the Installation Manual,577013-839 or
<br /> 577013-964.May also be connected to non-hazardous locations peripheral equipment as specified in the installation manuals.
<br /> Intrinsically Safe Devices,Class I,Group D, Battery Box, Part Number 332425-001 only for connection to the intrinsically safe transmitter,
<br /> Part Number 332235-001,which is in turn only for connection to one:
<br /> Intrinsically safe probe, Form No.84739,85639,84689, 84629 or 84639 all followed by 0 or 1, followed by 0, 1,2, 3,4, 5,6 or 7,followed by 00
<br /> to 17 inclusive or 99;or Form No. B57080 followed by 1 or 2,followed by 0, 1,or 2,followed by 1 or 2.or
<br /> CCVP-Form No.861290-XXX;or
<br /> ISD Flow Meter-Part No.331847-XXX; or
<br /> ISD Pressure Sensor-Part No. 331946-XXX.
<br /> All suitable for use in Class 1,Group D when used and installed as specified in the Control Drawing 331940-012,
<br /> Battery Box,Part No.332425-001 only for connection to the Model Mag XL-RF intrinsically safe transmitter, Part No. 333062-XXX(where XXX
<br /> represent alphanumeric characters unrelated to safety certification).The Mag XL-RF intrinsically safe transmitter provides intrinsically safe outputs
<br /> for use in Class I Group D as specified in Control Drawing, 331940-009.
<br /> Associated apparatus for use in non-hazardous locations providing intrinsically safe circuit extensions for use in Class I,Division 1,
<br /> Group D hazardous locations,Liquid level gauge/leak detector,designated TLS-350,TLS 350-PC or TLS-3501 consisting of control unit Farm No.
<br /> 84709 followed by 0, 5 or 7,followed by 0,3,4, 5 or 6,followed by 0 or 2,suffixed 2 or 4; or designated TLS-350R or Simplicity consisting of
<br /> control unit Form No.84829 followed by 0, 1, 2, 3,or 5, followed by 0 or 1,followed by 0 or 2,followed by 2 or 4 or designated 4000 consisting of
<br /> control unit Form No.848390,followed by 5 or 8,followed by 00; May be provided with:
<br /> Overfill Alarm Form No. 790091-00 with or without an Acknowledgement Switch Form No. 790095-001;
<br /> Remote Display Unit,Form No.8478,followed by 8 or 9, followed by 0,followed by 1 or 2,followed by 1 or 2,followed by 1 or 2. Form No.
<br /> 847090-1 followed by 0, 1 or 2,followed by 2;
<br /> The control unit may be provided with a combination of Plug-in Modules Form Nos. 847490-001, 100, -101,-102, -103, -104,-105,-106,-109,
<br /> -110,-111,-202,-204, -206,-207,-208,-209, -210, -300,-301, 302, -303,-304,-305,-306,-309,-315,-316, -317,-326, -377, -340, -350,
<br /> 360, -370, -380, -400,-401,-410, -420,-430, -431,480 or Form No, 329359-001, 329360-001,332250-001 (only one can be provided),or
<br /> 332451-001. Form No. 847090-1,control unit may additionally be provided with Form No.847490 107 or-108 plug-in modules.
<br /> Advanced Application Module, Form No. 849090 followed by 5 or 8,followed by 00 to 16 inclusive and up to 16 liquid sensors; Form No. 7943
<br /> followed by 8 or 9,followed by 0,followed by-205, -301,302, -401,-404,407,-409 or-420; TLS-RF Console,up to Four may be connected to
<br /> intrinsically safe field wiring terminals but cannot be placed in the hazardous location.
<br /> May connect up to 64 of the intrinsically safe apparatus below.These devices have been evaluated for use in Class I,Division 1,Group D
<br /> hazardous locations when connected to the above in accordance with manual number 576013-879.
<br /> http://database.ul.com/cgi-bin/XYV/template/LiSEXT/I FRAME/showpage-html?name=E... 8/21/2009
<br />
|