My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2440
>
2300 - Underground Storage Tank Program
>
PR0527629
>
INSTALL_2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 10:58:43 AM
Creation date
11/4/2018 2:50:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2008
RECORD_ID
PR0527629
PE
2351
FACILITY_ID
FA0018721
FACILITY_NAME
Costco Wholesale #1031
STREET_NUMBER
2440
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2440 DANIELS ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DANIELS\2440\PR0527629\INSTALL 2008.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
397
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2'-0" <br /> 54'-3" <br /> TYP. 2'-0" <br /> w <br /> 20'-2 3/4" 17'-5 3/4" TYP. <br /> UNDERGROUND DETECTABLE TAPE HARRIS SMITH FIBERCAST 3" OVER 2" <br /> 16'-1 1/4" INDUSTRIES INC. MODEL #DU-03 OR55 61 PRODUCT SUPPLY LINE (TYP.) z Q <br /> EQUIVALENT. INSTALL 6" TO 12" BELOW <br /> SURFACE BASE OR SURFACE MATERIAL WHERE <br /> \ Q � <br /> COMPACTED BACK REQ'D. BY OWNERS ENGINEER o <br /> OBSERVATION PORT (TY ).) 10„ t0 16-1/2" FILL AS SPECIFIED Q <br /> / o a PAVING VARIES � � Z �j <br /> TYP. v CONCRETE ASPHALT . `�' a W ® LLL � <br /> N N _ ® Il <br /> PREMIUM UNL. 91 OCTANE U <br /> 30,000 GALLON I v ' `\ \\ \ \\//\� w o J J <br /> TANK 3 22" MANWAY w Y /\\//�\//\\/�\�. . _ ._ \/j��/%\�/%\\! Y z ® FQ- Z <br /> o a o m m Z <br /> 1 # x\\ " ® Z U Out <br /> 0 A <br /> g T-4 \iii\i\��% \��\��\i In Q Z o C� <br /> 1 z \ \ \ Z c c <br /> % OD a wyFp (D (n x N o w w �q LQ <br /> OQ ' MY \\/� \/\//\� Q cn a n_ m a V !� V Q O <br /> I- F- <br /> �4 <br /> a � N U <br /> rcc <br /> ,n Vl N N VI 's <br /> CY <br /> SMITH FIBERCAST 3" OVER 2" TANK #3 PRODUCT LINE M W <br /> 55 61 70 r o <br /> VAPOR RETURN UNE �, ,� o � <br /> TO 4" OVER 3" HEADER UNDISTURBED SOIL OR c' dj m <br /> COMPACT TO 95% o o p V- <br /> 22" MANWAY <br /> TANKS #1 OR #2 PRODUCT LINE <br /> o NOTE: NOTE: <br /> ALL PIPING TO SLOPE TO TANKS AT 1/4" PER FOOT MINIMUM PIPING BURIAL DEPTHS SHOWN ARE IN <br /> (1/8" PER FOOT MINIMUM). ACCORDANCE WITH SECTION 3.5.5.2 OF NFPA 30. <br /> (4)4N <br /> pical Piping Burial <br /> REGULAR UNL. 87 OCTANE <br /> 30,000 GALLON TO SCALE <br /> TANK #2 22" MANWAY <br /> rA <br /> I INw m " Q� — o d <br /> FLOAT CHECK VALVE mm <br /> PLN 9468G OVERFILL <br /> ® HUSKY 4885 PROTECTION SEE DETAIL "J" <br /> VENT CAP 13 2"X1" REDUCER ON SHEET T-6 <br /> 2"0 DIA. BLACK STEEL RISER (PAINT BUSHING FOR CONTINUATION WJ � <br /> WHITE) (TYP.) 2"0 DIA. BLACK STEEL VENT PIPE, N <br /> PRIME & PAINT WHITE (TYP ) w QO <br /> . <br /> BRAVO COMPRESSION FITTING (TYP.) J � 0) <br /> z 2" TEE AND 1/4" TEST PORT ® Q <br /> DOUBLE WALL TRANSITION 6' TO 8' ABOVE FINISH GRADE <br /> 22" MANWAY <br /> REINFORCED CONCRETE SLAB ABOVE SEE o t45 suMP N N SUPPORT BRACKET <br /> CIVIL DRAWING FOR SPECIFICATIONS I ° O PAINT WHITE <br /> BRINE SUMP RESERVOIR N ro <br /> 42 & HYDROSTATIC SENSOR o <br /> GRADE o ? 146 BRAVO VENT RACK O <br /> w_ .......:. - Q <br /> t7 t" RIGID CONDUIT & ® � (n <br /> PENETRATION FITTING it 2"0 DIA. BLACK <br /> STEEL VENT PIPE <br /> �J REGULAR UNL. 87 OCTANE Q5 z z a U <br /> 30,000TANK GALLON 22" MANWAY (TYP-) <br /> T-5 ' # 50 3" FRP BONDED FITTING �P I <br /> (TYP. 3) (TYP.) <br /> O A GRADE <br /> T-4 <br /> TO TANKS <br /> to <br /> — SMITH FIBERCAST 3" 2' TEE AND 11 <br /> 55 61 <br /> • v OVER 2' FRP VENT 1/4" TEST PORT <br /> a ¢ L LIQUID SUMP LINES (TYP.) �r�1 6' TO 8' ABOVE <br /> / 9B SENSOR ) FINISH GRADE <br /> w IL <br /> 31 2" X 18" FLEX N FX� U. <br /> CONNECTOR CONC. FOOTING, PER J O <br /> BRAVO SPECIFICATIONS <br /> 29 SECTION ELEVATION 4 <br /> �jC4 <br /> 18" MANHOLE ACCESS TO 22" MANWAY OUTLINE OF CONCRETE CROWN o F m s <br /> a <br /> ANNULAR MONITOR (TYP. 3) 18" MIN. OBSERVATION PORT (TYP.) Y/ NOTE: �V 0 <br /> 37"02" DEEP WATERTIGHT MANWAY WITH NOTE: PRIOR TO TESTING G.C. SHALL VERIFY TIGHTNESS OF MANWAY BOLTS. VERIFY BOLTS TO IN ORDER TO PROVIDE MECHANICAL FLEXIBILITY WITHIN <br /> BE SET PER MANUFACTURERS TORQUE SETTINGS AND ADJUST AS REQUIRED NP.). THE RIGID PIPING SYSTEM, PROVIDE AT LEAST 4 FEET OF a <br /> (2) 5 GALLON SPILL CONTAINERS WITH 7 ( 39'x10 3/4" DEEP WATERTIGHT STRAIGHT PIPE RUN .BEFORE A CHANGE IN DIRECTION OF 9� 0 FESSIo <br /> INTEGRAL DRAIN ASSEMBLIES AND Typical Tank Field Layout Plan 32 MANHOLE/LID ASSEMBLY FOR TURBINE E 30 DEGREES OR MORE. (NFPA 30A (2000 & 2003) D y ent Stack Detail <br /> REMOVABLE LIDS FOR EASY ACCESS. CARB /4 Yp y SUMP ENTRY (TYP. 3). A §5.3.3(2)), (UFC (2000) §7901 .11.7.2) ih <br /> STAGE I EVR COMPLIANT (TYP. 3) 1: SCALE: 3/8"=1'-O" (TYP. 2) T-Z NOT TO SCALE a Pato yA <br /> ALL TANK TANK TANK q ��Y1� <br /> TANKS #3 #2 #1 TO OTHER tF pF CA0 1�® <br /> 5 GALLON CONTAINMENT � rH-N�K-E-"� DISPENSERS B TO DISPENSER X <br /> FILL END T-g T-4 T-4 T-4 12" MANHOLE 151 } s \ <br /> 22 . TURBINE END " E <br /> 6 CLEARANCE T-3 SMITH FIBERCAST 4" OVER 3" z z <br /> 4" DIA. FRP OR SCH. 23 2 HIGH CROWN TYP. AROUND ALL BETWEEN CAP SMITH FIBERCAST 3" 61 70 <br /> 40 PVC RISER <br /> OPENINGS (SEE NOTE #2) AND GRADE VAPOR LINES (TYP.) <br /> SMITH FIBERCAST 3" OVER "SECONDARY" 45' 58 w <br /> DUAL FLOAT 55 61 CROSS-OVER ELBOW a H <br /> 2" PRODUCT AND VAPOR o & $ x <br /> s LINES (TYP.) SMITH FIBERCAST 2" 68 �' SMITH FIBERCAST 4" a .1 <br /> HYDROSTATIC SENSOR 24 I N 6" LOCKING I "PRIMARY" 45' ELBOW I 74 "SECONDARY" CROSS-OVER TEE <br /> TO TLS-350R MONITORING I � 4'-2" MIN. TO �'� 154 TEST WELL SMITH FIBERCAST 3" <br /> SYSTEM (TYP. 3) _ -:... T-0" MAX. COVER \ tl <br /> 6" PVC 153 PLUG "SECONDARY" 90' ELBOW 67 SLOPE <br /> COUPLER <br /> BRINE HYDROSTATIC --- 1536" <br /> 6' SLOTTED SOLID <br /> RESERVOIR I 1 15 PVC PIPING — — _ — a <br /> - SMITH FIBERCAST 2" — ° <br /> PVC PIPE ° c�2 <br /> "PRIMARY" 90' ELBOW 57 Z > M <br /> O � 4`0" REDUCER BUSHING 77 ° 65 SMITH FIBERCAST 3° o a N N <br /> PRIMARY" TEE N a o <br /> SET AT 95% x� z SMITH FIBERCAST 3" OVER 2" w aL — — — o <br /> CAPACITY 12" 30,000 GALLON DOUBLE WALL o PRODUCT AND VAPOR LINES 55 61 3"x2" REDUCER BUSHING 76 I z w z <br /> MAX. (TYP.) CONTAINMENT SOLUTIONS (TYP-) ii SMITH FIBERCAST 4" OVER 3" > M N � Sz <br /> UNDERGROUND FIBERGLASS a o 61 70 ¢ o C,4 r C6R N <br /> �' v VAPOR LINES (TYP.) CO Z <br /> STORAGE TANK x N z <br /> LU 04 <br /> IN-TANK GAUGE PROBE W/90% OVERFILL 35 36 37 N z N` 3 N N Z 1 <br /> DUAL POINT <br /> ... ai o <br /> DROP TUBE 11 ALARM CALIBRATION. INSTALL PER MFR'S ' {- ,O L <br /> N ! N N K <br /> REQMNT'S. SMITH FIBERCAST 4" � Y <br /> 24"x1/4" THICK STRIKER "SECONDARY" 90' 72 N <br /> FE-PETRO 2 H.P. 28 PLATE UNDER ALL ELBOW SLOPE <br /> SUBMERSIBLE PUMP OPENINGS BY TANK - � Sa <br /> MANUFACTURER (TYP.) :51 <br /> 45' FE-PETRO. INTAKE 28 b - TO TANKS <br /> 4" TO 6" MAX. FILTER SCREEN SMITH FIBERCAST 3" 63 <br /> (SEE NOTE #3) 6" a "PRIMARY" 90' ELBOW a w <br /> PEA GRAVEL BED & ` 1, ' �; r < o Y x 1 . 61 70 SMITH FIBERCAST 4" <br /> � 1 ' }.�.,.' x ' ! " -�'- �` � = OVER 3" VAPOR PVC CAPBACKFILL (TYPICAL) LINES (TYP.) <br /> � <br /> NOTE: <br /> E <br /> i <br /> THE TANK FILL END SHALL BE INSTALLED ONE NOTE: rn <br /> INCH LOWER ELEVATION THAN THE TANK L. z MIN. OTHER BRANCHES OF PRODUCT <br /> TURBINEENDTypical Tank Section Typical Fiberglass Reinforced Pipe Fittings <br /> g yPIPING AND VAPOR RECOVERY ® Fittings <br /> O!-•�1'- END OF TANK SYSTEM PIPED SIMILARLY. g <br /> �2 NOT TO SCALE a '- m <br /> T-2 SCALE: 3 8"= 0" N NN <br /> L <br />
The URL can be used to link to this page
Your browser does not support the video tag.