COMPLIANCE INFO 1999-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
508
>
2300 - Underground Storage Tank Program
>
PR0231057
>
COMPLIANCE INFO 1999-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 12:55:50 PM
Creation date
11/4/2018 3:09:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2006
RECORD_ID
PR0231057
PE
2361
FACILITY_ID
FA0003720
FACILITY_NAME
CHARTER WAY PETRO INC.
STREET_NUMBER
508
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16504016
CURRENT_STATUS
01
SITE_LOCATION
508 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DR MARTIN LUTHER KING JR\508\PR0231057\COMPLIANCE INFO 1999-2006.PDF
QuestysFileName
COMPLIANCE INFO 1999-2006
QuestysRecordDate
2/14/2018 7:25:41 PM
QuestysRecordID
3794706
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
214
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SWRCB,January2002 • • <br />' Page _ of <br />7. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps aze Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard L Professional Engineer <br />❑ Other (Specify) <br />I est \lethod Used ❑ Pressure— — <br />❑Vacuum Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used:Equipment Resolution <br />Fill Sump # Fill Sump # FiII Sum # <br />.G,mn n;�meo. P Fill Sump # <br />Height from Tank Top to Top of <br />Hi hest Piping Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />CuuaitionofSump pno, to <br />Wait time between applying <br />Pressure/vacuum/water and <br />starting test: <br />Test Start Time. <br />Test <br />ra>�ran inresnoia or t ritena: <br />Test Result: <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass <br />❑ Fail <br />11 Pass <br />❑Fail <br />Is there a sensor in the sump? <br />❑ Yes -- No <br />❑ Yes <br />❑ No <br />❑ Yes <br />❑ No <br />❑ Yes <br />❑ No <br />Does the sensor alarm when <br />either product or water is <br />G Yes ❑ No n NA <br />❑ Yes ❑ No <br />[INA <br />❑ Yes ❑ No <br />'_- NA <br />❑Yes ❑ No <br />❑ <br />detected? <br />NA <br />Was sensor removed for testing? <br />Yes ❑ No ❑ NA <br />❑ Yes ❑ No <br />❑ NA <br />❑ Yes ❑ No <br />❑ NA <br />❑ Yes ❑ No <br />❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />—"Yes ❑ No ❑ NA <br />❑ Yes ❑ NTo <br />❑ NA <br />❑ Yes ❑ No <br />❑ NA <br />❑Yes ❑ No <br />❑ NA <br />COM m entS — (include information on repairs made prior to testhrg and ),ecommeirded follow up for failed tests) <br />