Laserfiche WebLink
DATE -111102- <br />SAN <br />1a102SAN JOAQUIN COUNTY PR# <br />ENVIRONMENTAL HEALTH DEPART NT PAGE=� <br />304 E. Weber Ave., Third Floor, Stockton, CA 95202 <br />(209) 468-3420 <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility NameCVeVf 0Q Facility Address �o`� �) • Cl�q�}� Wq �_ <br />Faciity Contact Svrin4U SAS n 1 Title_6 WAt2 Phone # <br />UST# Product UST#_Product UST#_Product UST#_Product <br />Overfill Prevention: ❑ AudiblefVisual D Mechanical Monitoring Panel: <br />Piping System: D Gravity D Pressure D Suction Violations: ❑Minor ❑Major <br />Automatic Pump Shut Down Satisfies CCR 2636 D Yes D No Dispenser Pan: D Yes D No <br />INSPECTION TYPE: I iRoutine DMonitoring Certification DComplaint Dlnstall ❑Removal ❑Repair/Upgrade <br />COMPANY NAME: TECHNICIAN NAME: PHONE: <br />VIOLATION(S) <br />The above facility is not in compliance with the following <br />section(s) of Health & Safety Code (HSC) and/or <br />California Code of Regulations <br />(CCR): <br />1 HSC 25284 Permit to operate <br />20 CCR 2712 (b) Maintenance & monitoring <br />2 CCR 2637 Secondary cont testing (6 <br />/ month/36 month) <br />records <br />21 CCR 2636 (f)(4) Annual line tightness test <br />detector test <br />3 V CCR 2711(b) & (c) Current State Forms A & B <br />22 CCR 2630 (d) Annual line leak <br />1!° 4HSC 25292.2 Certification of financial <br />23 CCR 2630 (d) Annual monitoring certification <br />responsibility and letter from <br />24 CCR 2643 (d) Daily monitoring of suction <br />chief financial officer <br />piping that is not continuously <br />5 CCR 2630 (d) Continuous monitoring system <br />monitored <br />25 CCR 2643 (d) Triennial tightness test of <br />for UST system <br />6 CCR 2636 (c)(1) All releases in secondary piping <br />suction piping that is not <br />flow to a collection sump <br />continuously monitored <br />26 CCR 2643 (e) Biennial tightness test of gray% <br />7 HSC 25291 (e) Water in secondary (20) cont <br />8 HSC 25291 (f) Automatic line leak detector(s) <br />piping that is not continuously <br />9 CCR 2636 (f)(1) Continuous monitoring system <br />monitored <br />27 CCR 2662 Upgrade requirements for US - <br />for underground piping <br />system <br />10 CCR 2632 (c)(2) Continuous monitoring system <br />28 CCR 2661 Permit to repair UST system <br />for UST <br />11 HSC 25291(a)(2) Secondary containment for <br />29 HSC 25286 (a) Permit to alter monitoring <br />UST is tight <br />12 CCR 2636 (f)(1) Continuous monitoring system <br />system <br />30 HSC 25298 (a) Illegal abandonment of UST <br />for dispenser system <br />system <br />31 HSC 25298 (b) Permit to temporarily close U: <br />13 CCR 2635 (b)(1) Spill container <br />system <br />14 CCR 2635 (b)(2) Overfill prevention system <br />15 CCR 2631 (a) Primary containment is product- <br />32 HSC 25298 (c) Permit to close UST system <br />tight <br />33 HSC 25291 (e) Water in 20 cont analyzed an( <br />16 HSC 25292.1 UST system is operated to <br />prevent unauthorized release <br />properly disposed of <br />34 CCR 2640 (e) Single wall component within <br />17 CCR 2650 Recording/reporting <br />1 000'of Public Well, no ELD <br />35 CCR 2635(a)(2)(A) Cathodic protection testing <br />unauthorized release <br />1CCCR 2632 (d) Monitoring & response plan <br />36 H&SC 25299(a)(9) Disabling leak detect. device! <br />19CR 2712 (i) Monitoring & response plan is <br />37 Violation(s) not listed above <br />on site <br />lu't' PHONE: 6 �( <br />EHD INSPECTOR: Von rr ,! <br />---`"I.1111 .. > TITIF• PHONE: 2,115 S. 7L/C/b <br />�.�,Tmn icrnuco �.e., vtmo� <br />