Laserfiche WebLink
T 3:DIESEL • TST EARLY STOP:DISABLED <br /> PRODUCT CODE 3 <br /> THERMAL COEFF : .000450 LEAK TEST REPORT FORMAT <br /> TANK DIAMETER 112.00 NORMAL <br /> TANK PROFILE 1 PT <br /> FULL VOL 12220 <br /> FLOAT SIZE: 2.0 IN. <br /> T 2:91 <br /> PRODUCT CODE 2 WATER WARNING 1 .0 <br /> THERMAL COEFF : .000700 HIGH WATER LIMIT: 2.0 <br /> TANK DIAMETER 112.00 WATER ALARM FILTER: LOW <br /> TANK PROFILE 1 PT <br /> FULL VOL 12220 MAX OR LABEL VOL: 12220 <br /> OVERFILL LIMIT 90% PRESSURE LINE LEAK SETUP. <br /> 10998 - - - - - - - - - - - - <br /> FLOAT SIZE: 4.0 IN. HIGH PRODUCT 95% <br /> 11609 <br /> WATER WARNING 1 .0 DELIVERY LIMIT 0% G 1 :87 <br /> HIGH WATER LIMIT: 2.0 0 <br /> WATER ALARM FILTER: LOW TYP:2.0i3.0IN FIBERGLASS <br /> LOW PRODUCT 800 2.OIN DIA LEN: 350 FEET <br /> MAX OR LABEL VOL: 12220 LEAK ALARM LIMIT: 99 <br /> OVERFILL LIMIT 90% SUDDEN LOSS LIMIT: 999 3.OIN DIA LEN: 0 FEET <br /> 10998 TANK TILT 0.00 <br /> HIGH PRODUCT .....-.. 95% PROBE OFFSET 0.00 SHUTDOWN RATE: 3.0 GPH <br /> 11609 LOW PRESSURE SHUTOFF:NO <br /> DELIVERY LIMIT 10% LOW PRESSURE 0 PSI <br /> 1222 ! SIPHON MANIFOLDED TANKS <br /> T#: NONE T 1 :87 <br /> LOW PRODUCT 800 LINE MANIFOLDED TANKS DISPENSE MODE: <br /> LEAK ALARM LIMIT: 99 T#: NONE STANDARD <br /> SUDDEN LOSS LIMIT: 999 SENSOR: VENTED <br /> TANK TILT 0.00 PRESSURE OFFSET: O.OPSI <br /> PROBE OFFSET 0.00 LEAK MIN PERIODIC: 0% <br /> 0 MECHANICAL BLENDER: NO <br /> SIPHON MANIFOLDED TANKS LEAK MIN ANNUAL 0% <br /> T#: NONE 0 <br /> LINE MANIFOLDED TANKS <br /> T#: NONE <br /> PERIODIC TEST TYPE <br /> STANDARD <br /> LEAK MIN PERIODIC: 0% <br /> 0 ANNUAL TEST FAIL <br /> ALARM DISABLED <br /> LEAK MIN ANNUAL 0% <br /> 0 PERIODIC TEST FAIL G 2:91 <br /> ALARM DISABLED <br /> I TVP:2.Oi3.OIN FIBERGLASS <br /> PERIODIC TEST TYPE GROSS TEST FAIL 2.01N DIA LEN: 350 FEET <br /> STANDARD ALARM DISABLED <br /> 3.OIN DIA LEN: 0 FEET <br /> ANNUAL TEST FAIL ANN TEST AVERAGING: OFF <br /> ALARM DISABLED PER TEST AVERAGING: OFF SHUTDOWN RATE: 3.0 GPH <br /> LOW PRESSURE SHUTOFF:NO <br /> PERIODIC TEST FAIL TANK TEST NOTIFY: OFF LOW PRESSURE 0 PSI <br /> ALARM DISABLED <br /> TNK TST SIPHON BREAKOFF T 2:91 <br /> GROSS TEST FAIL DISPENSE MODE: <br /> ALARM DISABLED DELIVERY DELAY 5 MIN STANDARD <br /> PUMP THRESHOLD 10.00% SENSOR: HIGH PRESSURE <br /> ANN TEST AVERAGING: OFF PRESSURE OFFSET: O.OPSI <br /> PER TEST AVERAGING: OFF <br /> MECHANICAL BLENDER: NO <br /> TANK TEST NOTIFY: OFF <br /> TNK TST SIPHON BREAKOFF <br /> DELIVERY DELAY 5 MIN <br /> PUMP THRESHOLD 10.00% <br /> LEAK TEST METHOD <br /> TEST ON DATE : ALL TANK G 3:DIESEL <br /> FEB 10, 2011 <br /> START TIME : DISABLED TYP:2.0i3.0IN FIBERGLASS <br /> TEST RATE :0.20 GAL/HR 2.OIN DIA LEN: 350 FEET <br /> f DURATION 2 HOURS <br /> "- 3.OIN DIA LEN: 0 FEET <br />