Laserfiche WebLink
IED PROGRAM CONSOLIDATED FORM TANK: TA0506494 <br /> PAN: PRO231057 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 FAC M FAOD03720 <br /> (two pages per tank) <br /> TYPE OF ACTIONEl I ❑ ❑ Page 4 of 7 <br /> (Chxl:wl.nem mh) NEW SITE PERMIT ❑ 4AMENDED PERMIT SCHANGE OF INFORMATION 6TEMPORARY SITE CLOSURE <br /> E] 7 PERMANENTLY CLOSED ON SITE <br /> F13RENEWAL PERMIT (SpaJy rcasw fm tical use ooh) °"q`P` " ❑8TANK REMOVED 430 <br /> BUSINESS NAME(S.me u FACILITY NAME a DBA-Doing B...nass As) FACILITY ID: PR#: I <br /> CHEVRON#92033* FA0003720 PR0231057 <br /> LOCATION WITHIN SITE(Opum.n 508 W CHARTER WAY,STOCKTON 431 <br /> PHONE <br /> 1.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 9 432 TANK MANUFACTURER 443 COMPARTMENTALIZED TANK ❑Yes [-]No 434 <br /> TA0506494 PLASTEEL If•Yar,mmpinoono page for .chmmpmsm.m <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 2/10/1997 12:0O:OOAM 12,000 <br /> ADDITIONAL DESCRIPTION(Fos Ixal,.seoan) 439 <br /> It.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® I.MOTOR VEHICLE FUEL ❑ In.REGULAR UNLEADED ❑ 2.LEADED ❑5.JET FUEL <br /> (Ifma v%nploc Pcu*)e T.pe) ❑ Ib.PREMIUM UNLEADED ❑ 3.DIESEL ❑6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ® Ica MIDGRADE UNLEADED ❑ 4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME(axxmMmals in-un pgo) 441 CAS#(f Halms Mmals msmmp page)) aa2 <br /> ❑ 4.HAZARDOUS WASTE <br /> (Ixladm Us Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ L SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Chxk aneimn on h) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-Primary tank ❑ I.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN m4 <br /> (Chx cwilanpnh) ❑2.STAINLESS STEEL ® STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100°/METHANOL <br /> REINFORCED PLASTIC(FRP) ❑99.OTHER <br /> TANK MATERIAL-secondary tank ❑ LEASE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Chxkamimmaoh) ❑ 2.STAINLESS STEEL ❑ 4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE WAW/e METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ L RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 44e DATE INSTALLED 447 <br /> OR COATING <br /> (Check mm imn mh) ❑ 2ALKYD LINING ❑4PHENOLIC LINING ❑ 6UNLINED ❑99.OTHER <br /> (For tical useanly) <br /> OTHERCORROSION ❑ 1 MANUFACTURING CATHODIC ® 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 444 DATE INSTALLED a9 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Chxk on lmm mlr) 2SACRIFICW.ANODE ❑ 4 IMPRESSED CURRENT E] "OTHER <br /> ❑ (Fm lxel a<anh) <br /> SPILL AND OVERFILL YEAR INSTALLE450 TYPE(bw.Wl) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Chxkalldm.pp15) ❑ I SPILL CONTAINMENT 1,997.00 ❑ IALARM ❑ 3 FILL TUBE SHUTOFF VAL` <br /> ❑ 2 DROP TUBE ❑ 2 BALL ❑ 4 EXEMPT <br /> ❑ 3 STRIKER PLATE FLOAT <br /> rV.TANK LEAK DETECTION(A 1wnpdan orae-tonng program shall be sa6mwaa u uK Ix.Lgrnw.) <br /> IF SINGLE WALL TANK(Chxk A N.I.pph) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ I VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Chock monvn anh) <br /> ❑ 2AUTOMATIC TANK GAUGING(ATG) ❑ 6VADOSE ZONE <br /> ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3CONTIN000S ATG ❑ 7GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ STANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 1 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 1 TANK FILLED WITH INERT MATERIAL' 457 <br /> ❑Yea ❑ No <br /> UPCF(12/99 revised) <br />