COMPLIANCE INFO 2013-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
508
>
2300 - Underground Storage Tank Program
>
PR0231057
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:19 PM
Creation date
11/4/2018 3:15:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0231057
PE
2361
FACILITY_ID
FA0003720
FACILITY_NAME
CHARTER WAY PETRO INC.
STREET_NUMBER
508
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16504016
CURRENT_STATUS
01
SITE_LOCATION
508 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DR MARTIN LUTHER KING JR\508\PR0231057\COMPLIANCE INFO 2013-2015.PDF
QuestysFileName
COMPLIANCE INFO 2013-2015
QuestysRecordDate
2/15/2018 7:45:41 PM
QuestysRecordID
3796185
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
140
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • SWRCB,January 2006 <br /> Spill Bucket Testing Report Form <br /> This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br /> printouts from tests(f applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. <br /> 1. FACILITY INFORMATION <br /> Facility Name: Chevron I Date of Testing: 10/10/2013 <br /> Facility Address: 508 Charter Way, Stockton,Ca.95206 <br /> Facility Contact: Rinku I Phone: (209)465-3440 <br /> Date Local Agency Was Notified of Testing: 10-01-1,�, - <br /> Name <br /> -p - <br /> Name of Local Agency Inspector(fpresent during testing): Stacy Rivera <br /> 2. TESTING CONTRACTOR INFORMATION <br /> Company Name: Reliable Petroleum Services,Inc. <br /> Technician Conducting Test: Guadalupe Sanchez <br /> Credentials: x CSLB Contractor x ICC Service Tech. ❑SWRCB Tank Tester ❑Other(Specify) <br /> License Number(s): 883706 5250451 <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used: xHydrostatic ❑Vacuum ❑Other <br /> Test Equipment Used: Standard Tape Measure Equipment Resolution:N/A <br /> Identify Spill Bucket (By Tank 1 Tl: 87 Fill 2 T2: 91 Fill 3 T3: Diesel Fill 4 T4: <br /> Number, Stored Product, etc. <br /> Bucket Installation Type: x Direct Bury x Direct Bury x Direct Bury Direct Bury <br /> Contained in Sump Contained in Sump Contained in Sump Contained in Sum <br /> Bucket Diameter: 12" 12" 12" <br /> Bucket Depth: 13 ''/4" 131/4" 123/4" <br /> Wait time between applying 1 minute 1 minute 1 minute <br /> vacuum/water and start of test: <br /> Test Start Time(Tj): 9:49 a.m. 9:49 a.m. 9:49a.m. <br /> Initial Reading(Rj): 12 3/8" 12 5/8" 11 3/4" <br /> Test End Time(TF): 10:49 a.m. 10:49 a.m. 10:00 a.m. <br /> Final Reading(RF): 12 3/8" 12 5/8" 10 3/d' <br /> Test Duration(TF-Ti): 1 hr 1 hr 1 hr <br /> Change in Reading(RF-Rj): 0 0 0 <br /> Pass/Fail Threshold or 1/16" 1/16" 1/16" <br /> Criteria: <br /> Test Result: I x Pass ❑Fail x Pass ❑Fail Pass x Fail Pass ❑Fail <br /> Comments- (include information on repairs made prior to testing and recommended follow-up forfailed tests) <br /> Diesel spill bucket failed test and needs to be replaced <br /> CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> hereby certify that all the information contained in this report its true,accurate,and in full compliance with legal requirements. <br /> Technician'sSignat�e '41Date 10/10/2013 <br /> State laws and regulations do not currently require testing to be performed by a qualified contractor.However, local requirements <br /> may be more stringent. <br />
The URL can be used to link to this page
Your browser does not support the video tag.