My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 -2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
749
>
2300 - Underground Storage Tank Program
>
PR0231060
>
COMPLIANCE INFO 2013 -2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:19 PM
Creation date
11/4/2018 3:20:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 -2016
RECORD_ID
PR0231060
PE
2361
FACILITY_ID
FA0003870
FACILITY_NAME
SRH FOOD & GAS
STREET_NUMBER
749
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
14734309
CURRENT_STATUS
01
SITE_LOCATION
749 E DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DR MARTIN LUTHER KING JR\749\PR0231060\COMPLIANCE INFO 2013 -2016 .PDF
QuestysFileName
COMPLIANCE INFO 2013 -2016
QuestysRecordDate
3/28/2018 9:47:52 PM
QuestysRecordID
3839038
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
178
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. 9:FUEL ALARM <br /> TANK,#: 1 L10:FUEL ALARM ISD AIRFLOW METER MAP <br /> L 6:SENSOR OUT ALARM • ID SERIAL NUM LABEL <br /> L 7:SENSOR OUT ALARM ------------------------ <br /> IN-TANK ALARMS L B:SENSOR OUT ALARM 1 51360 1-2 <br /> T 1 :LOW PRODUCT ALARM L 9:SENSOR OUT ALARM 2 52853 3-4 <br /> L10:SENSOR OUT ALARM 3 51361 5-6 <br /> UID SENSOR ALMS L 6:SHORT ALARM 4 51791 7-8 <br /> LIQ <br /> L UIFUEL ALARM L 7:SHORT ALARM <br /> L L B:SHORT ALARM <br /> 7:FUEL ALARM <br /> L B:FUEL ALARM L 9:SHORT ALARM ISD FUEL GRADE HOSE MAP <br /> L 9:FUEL ALARM LIO:SHORT ALARM 1 2 3 4 <br /> L10:FUEL ALARM FP MHH MHH MHH MHH AA-- <br /> L 2:SENSOR OUT ALARM 01 201 901 301 5 U 1 <br /> L 7:SENSOR OUT ALARM 02 202 902 302 5 U 1 <br /> L B:SENSOR OUT ALARM 03 203 903 303 U U 2 <br /> L 9:SENSOR OUT ALARM 04 204 904 304 U U 2 <br /> L10:SENSOR OUT ALARM 05 205 905 305 5 U 3 <br /> L 2:SHORT ALARM 06 206 906 306 5 U 3 <br /> L 7:SHORT ALARM 07 207 907 307 U U 4 <br /> L B:SHORT ALARM 08 20T 908 308 U U 4 <br /> L 9:SHORT ALARM <br /> L10:SHORT ALARM SMARTSENSOR SETUP <br /> - - - - - - - - - - - LABEL TABLE <br /> ISD SITE ALARMS ------------------------ <br /> ISD GROSS PRES FOIL s 1 :1-2 ' 1 : UNASSIGNED <br /> ISD DEGRD PRES FAIL CATEGORY AIR FLOW METER 2: BLENDS <br /> ISD VAPOR LEAK FAIL 3: REGULAR <br /> ISD VP PRES--FAIL I s 2:3-4 4: MID GRADE <br /> ISD SETUP FAIL CATEGORY AIR FLOW METER 5: PREMIUM <br /> ISD HOSE ALARMS6: GOLD <br /> s 3:5-6 7: BRONZE <br /> ALL:GROSS COLLECT FAIL CATEGORY AIR FLOW METER 8: SILVER <br /> ALL:DEGRD COLLECT FAIL 9: BLEND2 <br /> ALL:FLOW COLLECT FAIL s 4:7-8 10: BLEND4 <br /> R 2:91 STP CATEGORY AIR FLOW METER <br /> TYPE: s 7:P-SENSOR <br /> STANDARD CATEGORY VAPOR PRESSURE <br /> NORMALLY CLOSED <br /> TANK #: 2 s 8:ATMP �. <br /> CATEGORY ATM P SENSOR <br /> IN-TANK ALARMS <br /> T 2:LEAK ALARM PMC SETUP <br /> T 2:LOW PRODUCT ALARM <br /> LIQUID SENSOR ALMS PMC VERSION: 01 .04 <br /> L 4:FUEL ALARM VAPOR PROCESSOR TYPE <br /> L 7:FUEL ALARM NONE <br /> L B:FUEL ALARM <br /> L 9:FUEL ALARM PROCESSOR CONTROL LEVEL: <br /> L10:FUEL ALARM NONE <br /> L 4:SENSOR OUT ALARM <br /> L 7:SENSOR OUT ALARM <br /> L 8:SENSOR OUT ALARM EVR/ISD SETUP <br /> L 9:SENSOR OUT ALARM <br /> L10:SENSOR OUT ALARM <br /> L 4:SHORT ALARM <br /> L 7:SHORT ALARM EVR TYPE: VACUUM ASSIST <br /> L B:SHORT ALARM VACUUM ASSIST TYPE <br /> L 9:SHORT ALARM HEALY VAC <br /> L10:SHORT ALARM ALARM HISTORY REPORT <br /> ISD SITE ALARMS NOZZLE A./L RANGE <br /> ISD GROSS ARES FAIL MAX: 1 .15 MIN: 0.95 -- SYSTEM ALARM -_--- <br /> ISD DEGRD PRES FAIL PAPER OUT <br /> VAPOR PROCESSOR TYPE MAR 26. 2013 8:44 PM <br /> ISD VAPOR LEAK FAIL <br /> NONE PRINTER ERROR <br /> ISD VP PRES FAIL <br /> ISD SETUP FAIL MAR 26, 2013 8:44 PM' <br /> ISD HOSE ALARMS ANALYSIS TIMES <br /> ALL:GROSS COLLECT FAIL TIME: 10:00 AM <br /> ALL:DEGRD COLLECT FAIL DELAY MINUTES: 1 <br /> ALL:FLOW COLLECT FAIL <br /> R 3:DSL STP ACCEPT HIGH ORVR: <br /> TYPE: DISABLED <br /> STANDARD I:;D HOSE TABLE <br /> NORMALLY CLOSED ID FP FI HL AA RR * x * * END <br /> --------- ------------- <br /> TANK #: . 3 01 01 01 02 01 02 <br /> 02 02 02 02 01 02 <br /> IN-TANK ALARMS 03 03 03 02 02 02 <br /> T 3:LOW PRODUCT ALARM 04 04 04 02 02 02 <br /> - - 05 05 05 02 03 02 <br /> LIQUID.SENSOR ALMS 06 06 06 02 03 02 <br /> - L6:FUEL ALARM 07 07 07 02 04 02 <br /> L 7:FUEL ALARM 08 OB 08 02 04 02 <br /> T. R:FUEL ALARM <br />
The URL can be used to link to this page
Your browser does not support the video tag.