Laserfiche WebLink
• SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.org/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> SRH Food & Gas May 31, 2011 <br /> Facility address: UST#/ 6 7 8 <br /> 749 E. Charter Way, Stockton Product 91 87 DSL <br /> Facility contact: TNW. Phone: <br /> Johnny Rizwan Owner (209) 271-2578 <br /> Monitoring panel: Piping system: Overfill prevention: violations: <br /> Veeder-Root TLS-350 Pressurized❑Suction❑Gravity QAud ble/visual ❑X M1-RDetect[]M2-RPrev❑M3-Both <br /> Inspection type: Designated operator: ICC exp.date: <br /> N Routine ©Monitoring Certification E]Installation ❑Other Dave Winkler <br /> On site Service Technician's name: ICC exp.date: Manufacturees training: <br /> Felix Ramirez 12/11/12 VR x. 6/28/12 <br /> VIOLATIONS v R <br /> # Code Section <br /> HSC=CA Health&Safe Code;CCR=CA Code of Regulations;V=Violation- RV=Re at Violation V <br /> 1 HSC 25284 No rmit to operate <br /> Secondary containment: (a)test not performed; (e)test report not submitted within 30 days;(f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department(EHD)at least 48 hours prior to <br /> conducting the test <br /> 3 CCR 2711 b Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 1 CCR 2632(b) Monitoring Program(Monitoring&Response Plans is not current or approved by the EHD <br /> 6 CCR 2712(i) Monitoring Ian,response plan, and/or operating permit and all conditions not onsite X <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6 Y (M7) <br /> years,written performance Claims pertaining to release detection systems for 5 years,or records of <br /> repairs, linings,and upgrades for the life of the tank. Monitoring records include: (1)date and time of X <br /> 7 CCR 2712(b) all monitoring or sampling;(2)monitoring equipment calibration and maintenance records;(3)results <br /> of any visual observations;(4)results of sample analysis performed a lab or in the field; (5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations,or other test results; (6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-January1, 1984 not performed (M11 <br /> 9 1 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitials ace of a double walled UST (M1 <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest o ortun (M1) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (M1) <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (M1) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 1 CCR 2636(c)(1) All releases in secondary pipingdo not flow to a collection sum <br /> 17 CCR 2636(f)(2) Line leak detector(s) not installed or failed to detect a3-gallon per hour leak at 10 psi pall <br /> 18 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means (M2) <br /> to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (11112) <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) 11112) <br /> 21 HSC 25291(e) Water in 20 containment not removed, analyzed&property disposed of <br /> Unauthorized release that:(c)did not escape secondary containment and Cleaned up within eight (M1) <br /> 22 CCR 2650 hours was not recorded;(e)escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a I CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b CCR 2715(b) Designated operator did not possess a current ICC UST System Operator certification <br /> EHD inspector: Received by: Title: <br /> EHD 2302- R 0413/10 Page3 UST INSPECTION REPORT <br />