COMPLIANCE INFO 1991 - 2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 1991 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 3:26:05 PM
Creation date
11/4/2018 3:36:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991 - 2004
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 1991 - 2004.PDF
QuestysFileName
COMPLIANCE INFO 1991 - 2004
QuestysRecordDate
4/25/2018 10:10:21 PM
QuestysRecordID
3869105
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
203
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALWORNLA .•a "" <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> �r <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY 1 NEW PERMITRENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE )TEM 0 2 INTERIM PERMIT 51-11 AMENDED PERMIT 0 $ TEMPORARY TANK CLOSURE ❑ e TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED, <br /> I. TANK DESCRIPTION cOMPLETEALLrrEMS— SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.4 E MANVFAG RJRED BY: <br /> G DATE 1NSTALLE0(MQ�OAYIYEAA) o, b` Lia D. TANK CAPACITY IN GALLONS: Lo)000 <br /> II.WANK CONTENTS IFA-1 IS MARKED.COMPLETE ITEM C, <br /> A, i MOTOR VEHICLE FUEL Z.4 OIL g. C, 1t PEGULAA UNLFJDED 9 DIESEL 5 AVIATIONG.AS <br /> Z PVAOLEUM 60 EMPTY PRODUCT Sm PREMIUM UNLEJIDED A GASOHOL 7 MMANOL <br /> fe MWADE URSAOED JETFUEL B MM <br /> a GHE741CAL pROOUtT 0.5 UNKNOWN Q 2 WASTE 2 LEADED &pq OTHF3I pEscRIBE pi rrEm o.ma ow) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S,R <br /> III, TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,13,AND C,AND ALL THAT APPLIIES IN BOX 17 AND E <br /> If <br /> A TYPE OF 1 DOUBLE WALL 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 NTM4kL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM Q 2 SINGLS WALL 1 SINGLE WALL IN A VAULT 1:1 99 OTHER <br /> B. TANK Ej I BARE STEEL 2 Z17AIlLESS STEEL 3 FIBERGLASS [�:) A STEEL CLAD W/FIBFAGLASS REINFORCED PLASTIC <br /> MATERIAL Q 5 CONCRETE e POLYVINYL CHLORIDE 7 ALUMINUM 0 B 100% METHANOL COMPATIBLE W/FRP <br /> (PTfnlAlry T61k) a p BRONZE 10 GALVANIZED STEEL 25 UNKNOWN 99 OTHER <br /> C.INTEREOR ❑ 1 RUBBER UNED 2 ALKYD UNNG a 3 EPDXY LINING � A PHENOLIC LINING <br /> LINING OR 5 OLASS UMNO e UNLINED 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO— <br /> D.EXTERIOR I POLYETHYLENE WRAP 2 COATING 3,VINYL WRAP A FIBERGLASS REINFORCER PLASTIC <br /> CORROSION 91 NONE 83 UNKNOWN 99 OTHER <br /> PROTECTION ❑ s cATHoOIc PROTECTION Q [� 0 <br /> E.SPILL AND OVI=AFILL,MSPILL.CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> CROP T1JBE YES NO STRIKER PLATE YES NO DE5PfNfiER CONTAINIV YEb NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH 1F APPLICABLE <br /> A. SYSMM TYPE A@ 1 SUCTION A U 2 PAESSURE A U 3 GRAVITY A U A FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION AQ I SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 45 UNKNOWN A U F9 OTHER <br /> C. MATERL4L AND A U I RARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A A F113CROLASS PIPE <br /> CORROSION A U E ALUMINUM A U H CONCRETE A U T STEEL WI CCATING A U 0 100:4 METHANOL COMPATIBLE W+FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 93 UNKNOWN A U w OTHER <br /> D. LEAK DETECTION 01 urc'a 2 . uRKTC. ❑I artl.WM14MUL A,,UM <br /> mncOED 9e on+eR <br /> V.TANK LEAK DETECTION <br /> 1 VISUAL CHECK 2 MANRREIDONCI ENTE 3 MONOZE CrOAING + GAUGING C TANK D.C MONITORING OUND WATER 6 ANNUAL <br /> TESiINGTANK <br /> 7MONTTORQNGTER <br /> INSTITIAL A SIR � 9 WEEKLY MANUAL 10 MMONTHOLY TANK 95 UNKNOWN 99 OTHER <br /> VL TANK CLOSURE INFORMATION(PERMANENT CLOSURE N-PLACE) <br /> 1,E9"IIMATED DATE LAST USED IMOIDAYNFO 2,ESTIMATED OUANTITY OF 3.WAS TANK RL L FD WITH <br /> SUBVANCfi REMAINING GALLONS INERT MATERIAL 7 YES NO <br /> THIS FORM NAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND BOAREICT <br /> TANK OWNER'S NAME / DATE <br /> (PRINTR &S;WATUFM <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY f JURISD=CN A FACILPTY R TANK 0 <br /> STATE I.D:# Ll I 1 11 - i I <br /> PERMIT NUMBER PERMIT APPROVED BWDATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FOMM A.UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST Be COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PLAN. FILE THIS FORM WITH THE LOCAL AGENCY IMPLtMEH LNG THE UNDERGROUND STORAGE TANK REGULATIONS <br /> Fcmm <br />