My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1991 - 2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 1991 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 3:26:05 PM
Creation date
11/4/2018 3:36:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991 - 2004
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 1991 - 2004.PDF
QuestysFileName
COMPLIANCE INFO 1991 - 2004
QuestysRecordDate
4/25/2018 10:10:21 PM
QuestysRecordID
3869105
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
203
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> ...as easy as 1-2-3 <br /> 23 Standard Installati011 <br /> Ground Level <br /> Type of Applications <br /> Motor Fueis <br /> Chemicals <br /> Performance Specifications' <br /> ± 4.00075" Precision of Liquid Level <br /> ± 6 gallons Volume of Fuel Probe <br /> 0.530F/± 4.0021°F Temperature Accuracy/Resolution <br /> 0.3" Water Sensor Threshold Product Level <br /> 0.27% Inventory Flow Through Accuracy <br /> Accuracy Dependencies <br /> endencies <br /> In Leak/Level Gauging <br /> 9 9 <br /> multiple RTDs Probe Temperature sensors <br /> 128 #of Strapping in Points Applied <br /> Field/Factor Apply S <br /> Y Set Pp Y P ecific Gravity <br /> Field/Factory Set Tank,Type and Size <br /> Statistical Algorithm Software Applied Water Level <br /> Digital/Telemetry Noise Immunity <br /> Product Features <br /> Power Requirements: Less than 25 watts. <br /> 32 Mins.' Leak Test Times Required at 0.2 Gal/hr <br /> 75 Mins.' Leak Test Times Required 0.05 Gal/hr <br /> LCI?Display <br /> 1-8 Multi Tank Monitoring Capability <br /> Manifolded Tanks EXCEEDS REGULATORY REQUIREMENTS <br /> RS-232 Communications Interface <br /> Printer <br /> Programmable Alarms: The EASI Level-Tru' has been The Level-Tru"'s leak detection <br /> Overfill <br /> High Water proven capable of exceeding the Fed- performance meets all the above <br /> Theft <br /> Leak Rate eral Register's EPA Proposed Rules and does so in only 32 minutes, in <br /> Low Inventory <br /> Security [Section 280.41 (S�� requires an eight foot diameter, 8000 gallon <br /> Probe Diagnostics that product level monitoring be tank, filled to 95 Fo capacity.The <br /> Leak Test Validity—PASS,FAIL,INVALID p � <br /> Reports: conducted to detect a 0.2 gallons per Level-Tru- inventory reconciliation <br /> All Alarms <br /> Inventory Status hour leak rate, with a probability of controls exceed the Federal Regis- <br /> Delivery <br /> Leak Detect detection of 0.99 and a probability ter rules above, in that a release <br /> Leak Test Parameters <br /> Net Inventory Reconcilliation offaIse alarm of 0.01... Inventory greater than 0.277o of monthly <br /> Dimensions reconciliation controls must include flow through will be detected. <br /> Console: reconciliation of inputs,udthdrawals, These performance specifications <br /> 15" Width <br /> 11.5" Height and stored inventory each operating of the Level Tru'~have been vali- <br /> 85" Depth day so that a release greater than 5 dated by an independent laboratory. <br /> 251bs. Weight <br /> Probe: percent of flow through on a weekly An executive summary of the report <br /> Up to 30 ft. Length <br /> 2".3",4" Tank Openings basis or 0.5percent offlow through on is available upon written request, <br /> 20 lbs.- Weight a monthly basis will be detected..." subject to EASI's approval. <br /> w/installation kit S' � pp <br /> Approvals/Standards <br /> U.L. <br /> CSA <br /> FM <br /> FCC <br /> MIL-STD 810C Environment <br /> `Validated ro <br /> by Independent Laboratory. ro <br /> Based on a 8,000 gallons tank at 95%fill capacity. EASI is proud to equip you with And Safety,Inc, <br /> the most reliable level monitoring 2350 Mission College Blvd. <br /> and leak detection available. Please Suite 1000 <br /> feel free to contact the EASI Sales Santa Clara, CA 95054 <br /> Department at(408)982-3866 or <br /> FAX 408-982-3887. ©1980 Environment And Safety,Inc. <br />