My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1991 - 2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 1991 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 3:26:05 PM
Creation date
11/4/2018 3:36:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991 - 2004
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 1991 - 2004.PDF
QuestysFileName
COMPLIANCE INFO 1991 - 2004
QuestysRecordDate
4/25/2018 10:10:21 PM
QuestysRecordID
3869105
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
203
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A-TEAM CONSULTING <br /> February 1,2001 <br /> Mr. Steve Sasson <br /> San Joaquin County Public Health Services <br /> 304 E. Weber Avenue,Third Floor <br /> Stockton CA 95202 <br /> RE: Notice of Violation at Ryder Truck Rental#1071 (Stockton CA) <br /> Response and Summary Documentation <br /> Dear Mr. Sasson: <br /> Based on our recent phone conversation and per your request,the following information summarizes Ryder Truck Rental,Inc. <br /> (Ryder)response to your inspection performed on December 21, 2000. Please note that Tanknology provides assistance and tank- <br /> related compliance services to Ryder,and as necessary,will assist Ryder with any additional compliance issues.Tanknology <br /> addressed the following items in a letter submitted to you on January 17, 2001. <br /> Cate o 4-Certificate of Financial Res onsibili <br /> Tanknology submitted the Certificate of Financial Responsibility for this site to you on 411712000. <br /> Category 5-Continuous Monitoring System for UST System <br /> a. The remotely monitored Veeder-Root TLS 350 ATG console has now been programmed so that facility personnel will <br /> see and hear all compliance-related alarms. <br /> b. The used oil tank either lacks an annular sensor,or that its sensor(if present)is not properly configured. We do know <br /> that the 1,000-gallon used oil tank was installed in 1990 with the other underground storage tanks(UST)which are <br /> double wall fiberglass constructed. Ryder is planning to up-grade the fuel dispensers in die second quarter of 2001 and <br /> the select contractor will investigate the used oil tank to determine if a riser has been resurfaced and if a probe line exists. <br /> Corrections and up-grades to the annular sensor and as necessary will be performed at this time. <br /> Category 7-Secondary Containment for UST is Water-Tight <br /> The source of the fluids in the diesel and oil sumps may be due to line tightness testing activities performed on December 21, 2000 <br /> or possibly from surface water infiltration- Each tank sump was inspected and absorbent pads were applied to the fluids within the <br /> enclosure. Approximately 2.5 total gallons of fluids were removed. As part of routine service, Safety Kleen will recycle the <br /> absorbent pads. Weekly and or daily inspections will be performed at each tank sump to evaluate if fluids have re-accumulated. If <br /> fluid ingress continues,Ryder will provide a remedy and submit an addendum to this response and summary letter. <br /> Cate o 8-Automatic Line Leak Detector <br /> Tanknology replaced the automatic line leak detector the day of your inspection,and the new detector passed the test. Test <br /> documentation was submitted by Tanknology. <br /> In surmmary,Ryder will initiate service island upgrades in the near future. Pi <br /> be made. Ryder will provide you with additional information as it becomes <br /> Inc at your convenience if you have any additional questions or comments. <br /> Sincerely, A-Team Consulting <br /> AAnthony R. Herald <br /> "I -- Registered Professional Geologist <br /> Anthony R. Herald <br /> 94 Angeles Vista Circle 'L- (505)286-0911 <br /> cc: M. Armstrong, C.Bernott, M.L.Douglas, Sandia Park, NM 87047 F-1505)286-0990 <br /> email: ATEAM@flash.net M - (505)720=0711 <br /> 94 Angeles Vista Circle • Sandia Park NM 87047• (505)286-0911 (505)286-0711 •e-mail:riderunalflashnet <br />
The URL can be used to link to this page
Your browser does not support the video tag.