My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 2007 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:11 PM
Creation date
11/4/2018 3:46:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2010
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 2007 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2007 - 2010
QuestysRecordDate
4/25/2018 11:45:33 PM
QuestysRecordID
3869854
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
From; 0 011 22009 17:04 #347 F.0101011 <br />0 rq Ttin c. r oris <br />RLC <br />" <br />PH J1 Elm" <br />EVi4'OF 9.3 - <br />9. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Page 9 <br />Test Method Developed By: _ UDC Manufacturer X industry Standard _' Professional Engineer <br />0 Other (Specify) <br />Test Method Used: i.7 Pressure -; Vacuum X Hydrostatic <br />Other (Sped) <br />Test Equipment Used: Ronan HY Precision Test Equipment Equipment Resolution: 0.0000" <br />Master 1/2 Master 4 Satellite 2 Satellite l Satellite 4 <br />UDC Manufacturer: Fiberglass Fiberglass Fiberglass Fiberglass Fiberglass <br />UDC Material: <br />Fiberglass Fiberglass <br />Fiberglass Fiberglass <br />Fiberglass <br />UDC Depth: <br />32" 32" <br />32" 32" <br />32" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />11 7" <br />10" 10" <br />—7" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />—91, _91" <br />—6" —6" <br />_91. <br />Condition of UDC prior to <br />Clean Clean <br />Clean Clean <br />Clean <br />testing: <br />Portion of UDC Tested' <br />--14' t a" <br />13" 14" <br />--14" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />xYes -_'No ryes F.,,No <br />xYes UNo xYes `No <br />xYes 7_7No <br />1JYes •.- No <br />product and water)?' <br />QNA DNA <br />INA _NA <br />!NA <br />DNA <br />Turbine shutdown response time <br />--6 sec --6 sec <br />—6 sec —6 sec <br />--6 sec <br />Is system programmed for fail- <br />xYes CNo xYes 1 -No <br />xYes DNo x'ltes ']No <br />xYes CJNo <br />C:Yes !'.,No <br />safe shutdown'?* <br />:'NA `-INA <br />uNA LINA <br />ONA <br />DNA <br />Was fail-safe verified to be <br />xyes i.:1No xYes -7No <br />xYes 3No xYes 1'!No <br />xYes 12 -No <br />.DYes ONo <br />operational?' <br />CNA :INA <br />f]NA r'NA <br />QNA <br />[_'NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />Test Start Time: <br />8:00 ani 8:00 am <br />9:00 am 9:00 am <br />10:00 am <br />Initial R.eadang (Rl): <br />Test End Time: <br />8:30 am 8:30 am <br />9:30 am 9:30 am <br />10:30 am <br />Final Reading (RF): <br />Test Duration: <br />30 minutes <br />Change in Reading (REr-RI). <br />0 0 0 1 0 0 <br />Pass/Fail Threshold or Criteria: <br />PASS =No Lass or Loss of 0.0020" or less in 30 minutes <br />Test R+ sulci <br />xPass ❑Fail <br />xPass ❑Fait <br />xPass ❑Fail <br />xPam DFaii <br />xPass ❑Fail <br />OPass ❑Fiil <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced and <br />Yes <br />Yes <br />Yes <br />Yes <br />Yes <br />verified functional after testing'? <br />Comments — (inchiele inl6 ntation on repairs made prior to testing, and recomniended,follotiv-tip for failed tests) <br />` If the entire depth of the UDC is not tested, specify how much was tested. if the answer to Agy of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />