My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 2007 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:11 PM
Creation date
11/4/2018 3:46:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2010
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 2007 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2007 - 2010
QuestysRecordDate
4/25/2018 11:45:33 PM
QuestysRecordID
3869854
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
From. -0 01/27/2009 17:06 #348 P.0031011 <br />4 ��Y AGS OR 5 <br />R C <br />Ura w�t�a�' <br />4. TANK ANNULAR TESTING <br />Page 2 <br />Test Method Developed ):3y: ;:; Tank Manufacturer X Industry Standard iJ Professional Engineer <br />L ,; Other (:Speci&) <br />Test Method Used: ] Pressure X Vacuum 01 Hydrostatic <br />? Other (Spe'cii) <br />Test Equipment Used: <br />Equipment Resolution: <br />Is Tank Exempt From Testing?' <br />Tank # <br />Tank #_._._.I <br />Tank #____.__.- Tank # <br />Yes -" No <br />Yes i_ No <br />n Yes - No <br />Yes `; No <br />Tank Capacity: <br />Tank Material: <br />Tank Manufacturer: <br />— <br />Product Stored: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />Initial Reading (R.i): <br />i <br />Test End Time: <br />Final Reading (RE): <br />Test Duration: <br />Change in Reading (RF -Rt): <br />Pass/Fail Threshold or Criteria: <br />One hour, no loss <br />TestResult: <br />O'Pass 0 Fail <br />0 Pass 0 Fail <br />0 Pass 11 Fail <br />❑ Pass 0 Fail <br />Was sensor removed for testing? <br />_: Yes -- No [INA <br />la Yes D No LINA <br />_Yes; 'i:] No NA <br />0 Yes GNo 0 NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />Yes ' No 0 NA <br />Yes -1 No ,: i NA <br />?Yes L No NA <br />1 Yes No Ll NA <br />Comments — (include inforination on repairs nude prior to testing, and )-t?coinmettded fallow -tip fai•fuil(-,d tests) <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systeuas that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. lCalifornia Code of Regulations, Title 23, Section 2637(a)(6) <br />CADoemnents and Settingslhill\Local 5ettings�Temporary Internet Files10LK1kRyder patt3.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.