Laserfiche WebLink
' Frbrrr: 0 01/? 12009 17:07 #348 P.0101011 <br />B A Q H <br />9. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Page 9 <br />Test. Method Developed By: C UDC Manufacturer X Industry Standard Professional Engineer - <br />D Other (Specijj) <br />Test Method Used: F] Pressure :-s Vacuum X Hydrostatic <br />-i Other (Specify) <br />Test Equipment Used: Ronan HY Precision Test Equipment Equipment Resolution: 0.0000" <br />.• - - r•�= <br />UDC # UDC # UDC # UDC # UDC # UDC # <br />UDC Manufacturer: <br />UDC Material: <br />UDC Depth: <br />Height from UDC Bottom to Top <br />of Highest Pipina Penetration: <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />testm : <br />Portion of UDC Tested' <br />Does turbine shut down when <br />]Yes u 7Y Ir'No <br />Yes DNo <br />CYes f CNo <br />i]Yec Na <br />'Yes =.1No <br />UDC sensor detects liquid (both <br />-No <br />FNA _INA <br />71NA <br />3NA <br />ENA <br />7NA <br />product and water)?` <br />Turbine shutdown.response time <br />1s system programmed for fail- <br />DYes [No CYes i. No <br />DYes i]No <br />::Yes CNo <br />[ryes ❑No <br />! Yes JNo <br />safe shutdown?` <br />: NA DNA <br />CNA <br />CNA <br />_.NA <br />:DNA <br />Was fail-safe verified to be <br />DYes ,'-]No ❑Yes !:No <br />i='Yes CNo <br />DYes f.3No <br />! ]Yes �.-1No <br />_.lyes L -No <br />operational?* <br />:INA DNA <br />CNA <br />CNA <br />'NA <br />CNA <br />Wait time between applying <br />pressure/vacuurn/water and <br />starting test <br />Test Start Time: <br />Initial Reading (RI): <br />Test End Time: <br />Final Reading (RI.): <br />Test Duration: <br />Change in Reading (RF -RI): <br />Pass/Fail Threshold or Criteria: <br />PASS =No Loss or Loss of 0.0020" or less in 12 minutes <br />Test Resutt: <br />OPass ❑Fail <br />❑Pass OFail <br />DPass D ail <br />©Pass 131.ifll' ❑Pass❑Fail <br />DPass ❑Fail <br />Was sensor removed for testing'? <br />Was sensor properly replaced and <br />verified functional after testing? <br />Comments — (include, it formation on rel)air°s i�iacle pt-ior to tesrin , and i-econrmended folloii�-up,fvr• fitile(Itests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. if the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />C:',Doculnents and 5ettinps,bill'+Local 5ettin$sl'reniryorm lnteme3 Files\OLKilRydLT partIdoe <br />