My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 3:03:36 PM
Creation date
11/4/2018 3:52:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\BILLING 2015.PDF
QuestysFileName
BILLING 2015
QuestysRecordDate
4/26/2018 7:57:02 PM
QuestysRecordID
3871781
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br /> (two pages per tank) <br /> Page of 77 <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one ham only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-forlocal uaconly) (Specify name-for locsllme only) ❑ 8 TANKREMOVED 430 <br /> BUSIN SS NAME(Same FACILITY NAME oa�r DORR-D�oy'p�gEusinrc7es Aa) FACILITYID: <br /> Rl Yuk_V1 1 10cV ' t� l l 3 <br /> LOCATION WITHIN SITE(Optional) 431 <br /> I.TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK[D$ 032 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes NJ No 434 <br /> 00I`IY IP'Yes",complete ane page for each cone marenl. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> Qk L40 21, C00 <br /> ADDITIONAL DESCRIPTION(Far local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ❑1. MOTOR VEHICLE FUEL ❑la. REGULAR UNLEADED ❑2. LEADED 5. JET FUEL <br /> Oftearkedcomplem Penolcum Type) ❑lb. PREMIUM UNLEADED 03. DIESEL ❑6. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED ❑4. GASOHOL [199.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Haroad as Mannish Inventorypage) 041 CAS#(fiom Hazardous Materials Invnnmry page) 442 <br /> [14. HAZARDOUS WASTE <br /> (Include Used Dip <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK I. SINGLE WALL 3. SINGLE WALL WITH LJ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER El 95, UNKNOWN <br /> 02, DOUBLE WALL ❑4. SIGNLE WALL IN VAULT El99. OTHER <br /> TANK MATERIAL-primary lank 1. BARE STEEL 3. FIBERGLASS/PLASTIC LJ 5. CONCRETE 95. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8.i FRP COMPTIBLE W/11010%METHANOL [199.OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank 1. BARE STEEL 3. FIBERGLASS/PLASTIC I. CONCRETE 95. UNKNOWN 445 <br /> (Cbeckone iternmay) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS [311. FRP COMPTIBLE W/100%METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑(0.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING 0 1.RUBBER LINED Lj 3.EPDXY LINING �,U 5.GLASS LININ(( 95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING x16 UNLINED ❑99 OTHER <br /> (Cls ckonc item only) (Far heel use only) <br /> OTHER CORROSION ❑I MANUFACTURED CATHODIC �aDp,9{(3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 4411 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (Far local use only) <br /> SPILL AND OVERFILL/ YEAR INSTALLED 11ga 450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENTNEAR INSTALLED ( 40 452 <br /> (Check all mp <br /> that apply) 1 SPILL CONTAINMENT ❑I ALARM ❑3 FILL TUBE SHUT OFF VALVE <br /> ❑2 DROP TUBE ❑2 BALL FLOAT ❑4 EXEMPT <br /> ❑3 STRIKER PLATE <br /> IV.TANK LEAK DETECTION(A description of the northering progumn shall be submined to me local Marcy.) <br /> IF SINGLE WALL TANK(Check all ritually) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one item only) <br /> ❑I VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> 2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ❑2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION [18 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 1 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> UPCF(12/99 revised) 10 Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.