My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1502
>
2300 - Underground Storage Tank Program
>
PR0231082
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2020 12:24:33 PM
Creation date
11/4/2018 4:00:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231082
PE
2381
FACILITY_ID
FA0003794
FACILITY_NAME
CIRCLE K STORE #5643*
STREET_NUMBER
1502
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12708018
CURRENT_STATUS
02
SITE_LOCATION
1502 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\1502\PR0231082\COMPLIANCE INFO 1998 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 1998 - 2008
QuestysRecordDate
8/9/2017 8:52:33 PM
QuestysRecordID
72797
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-HUNTtRIENVIRONMENTAL SERVICES, INC. <br />18350 MT. LANGLEY STREET, SUITE 101 <br />FOUNTAIN VALLEY, CA 92708 <br />800-247-9014 800-247-2186 <br />CUSTOMER: UNOCAL <br />ADDRESS: 1502 N. EL MWO <br />STMYTDN, CA <br />SYSTEM TANK SIZE NATER <br />--' <br />FINAL TEST RESULTS <br />TEST DATE: 4/25/88 <br />LOCATION/IDENTIFICATIDN NO.: 4409 <br />TEST RESULTS SUMMARY <br />_______________ LEAK LOKATOR RESULTS <br />--------------------- <br />LEVEL ALR <br />I Stu 12000 92/FG 0 155 -.042 TIGHT <br />2 U/L 12000 92/FG 0 165 +.028 TIGHT <br />3 DIESEL 12000 92/FG 0 155 -.013 TIGHT <br />PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br />SYSTEM TYPE Of PUMP POUNDS POUNDS MINUTES PRODUCT PRODUCT CONCLUSION <br />NO. PRODUCT______ REMOTESUCTION__ _APPLIED___ HELD_____ HELD_____ LOSS CC'sLOSS DPH/RESULT_______ <br />S/U RED JACKET 50 48 10 PASS <br />2 U/L RED JACKET 50 50 10 PASS <br />3 DIESEL RED JACKET 50 50 10 PASS <br />NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br />DETAIL OF TEST RESULTS <br />*LEVEL - Inches from Tank Bottom to Test Level <br />ALP. - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br />CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness <br />CERTIFICATION CERTIFIED <br />This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br />LOKATOR according to all standard operating procedures. Those indicated as tight at full system meet the criterion <br />established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br />Tests Conducted and Certified By: Test Van No. 7 <br />Teas Manager: P. WHEELER <br />Tank Testing Specialist: S. ANDERSON <br />TEST <br />____TIME_______ <br />__LEAK_RATE <br />TEMPERATURE <br />ABSOLUTE <br />CHECK <br />SYSTEM <br />TEST LEVEL <br />CLOCK <br />DURATION <br />COMPENSATION <br />LEAK RATE <br />TEST <br />NO. PRODUCT <br />NO. (IN.) <br />STATE <br />(Hk MIN)_ <br />CC/DIV_ <br />CC/MIN_ <br />DELTA oE_CC/MIN <br />CC/MINSPH <br />Y/N________ <br />1 5/U <br />1 155 <br />1:40 <br />:60 <br />3.947 <br />+39.555 <br />+,082 42.2422.655 <br />-,042 <br />N <br />2 U/L <br />1 165 <br />4:20 <br />:60 <br />61.734 <br />+39.254 <br />+.075 +37.471 <br />+1.782 +,028 <br />N <br />3 DIESEL <br />1 155 <br />2:40 <br />:60 <br />4.878 <br />+6.624 <br />+,022 +7,494 <br />-.87 -.013 <br />N <br />*LEVEL - Inches from Tank Bottom to Test Level <br />ALP. - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br />CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness <br />CERTIFICATION CERTIFIED <br />This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br />LOKATOR according to all standard operating procedures. Those indicated as tight at full system meet the criterion <br />established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br />Tests Conducted and Certified By: Test Van No. 7 <br />Teas Manager: P. WHEELER <br />Tank Testing Specialist: S. ANDERSON <br />
The URL can be used to link to this page
Your browser does not support the video tag.