My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1502
>
2300 - Underground Storage Tank Program
>
PR0231082
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2020 12:24:33 PM
Creation date
11/4/2018 4:00:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231082
PE
2381
FACILITY_ID
FA0003794
FACILITY_NAME
CIRCLE K STORE #5643*
STREET_NUMBER
1502
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12708018
CURRENT_STATUS
02
SITE_LOCATION
1502 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\1502\PR0231082\COMPLIANCE INFO 1998 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 1998 - 2008
QuestysRecordDate
8/9/2017 8:52:33 PM
QuestysRecordID
72797
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V V <br /> RHL <br /> RE: UPGRADE PLAN FOR <br /> As per your request a review was made and this plan review revealed that it would not meet the <br /> minimum requirements for the 1998 upgradesC� bl&to include but not be limited t the <br /> following: <br /> 1. All information on the tanks are incomplete and must be provided in order to determine what <br /> will be needed in order to upgrade this tank system. Plans indicate that the tank is fiberglass <br /> and the "A" forms indicate that the tanks are steel clad. Please identify the actual tank types <br /> witch you intend to upgrade. Note that a special inspector will be required to provide a <br /> determination on either type of tank, for catholic protection and for the structural soundness <br /> of the tanks. The EHD must be onsite and observe all inspections of the tank system made <br /> by a special inspector. Specific requirements of the inspection will be outlined by the EHD <br /> depending on the type and age of the tank to be upgraded. (CCR title 23 section 2660 (1)) <br /> 2. Tanks that are single wall fiberglass or steel clad must have a site assessment prior to <br /> approval of the plan for upgrading. (CCR title 23 section 2660 (1)) Assessments are made <br /> after application to the EHD Site Mitigation Unit, attention Margaret Lagorio at 209-468-3449. <br /> 3. If the site is found to be contaminated, no further action will be permitted until a cleanup plan <br /> is approved. If tanks are approved to be left in place by the EHD after contamination is <br /> identified during the site assessment phase, a monitoring system must be installed witch <br /> meets the requirements of the Health and Safety Code section 25296 <br /> 4. Single wall pressurized lines cannot be left in place unless they were put in under a permit <br /> from the EHD. If these lines were not installed under permit and inspection, then the lines <br /> must be verified to have been properly installed by uncovering and inspection by a special <br /> inspector and observed by EHD staff. Sampling of the line area will also be require in order <br /> to determined if any unauthorized release has occurred. Sampling must be completed under <br /> EHD permit. (CCR title 23 section 2660 (1)(k)) <br /> 5. The tank and line monitoring system must be installed which i listed in G1134 and must <br /> meet the requirements of CCR Title 23 section 2666. ,, <br /> 6. If any evidence of corrosion is noted by the special inspector during the inspection of the <br /> undeground tank CCR title 23 section 2660(n) which refers to section 2635 (2a) (2b) will <br /> apply to a corrosion protection system. <br /> If you have any questions regarding this matter, please contact me at (209) 468-3446. <br /> Karen Furst, M.D., M.P.H. <br /> Health Officer <br /> Doug Wilson, Supervising R.E.H.S. <br /> Environmental Health Division <br /> DW/dw <br />
The URL can be used to link to this page
Your browser does not support the video tag.