E
>
EL DORADO
>
1502
>
2300 - Underground Storage Tank Program
>
PR0231082
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2020 12:24:33 PM
Creation date
11/4/2018 4:00:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231082
PE
2381
FACILITY_ID
FA0003794
FACILITY_NAME
CIRCLE K STORE #5643*
STREET_NUMBER
1502
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12708018
CURRENT_STATUS
02
SITE_LOCATION
1502 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\1502\PR0231082\COMPLIANCE INFO 1998 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 1998 - 2008
QuestysRecordDate
8/9/2017 8:52:33 PM
QuestysRecordID
72797
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br />CALIFORNIA MONTHLY <br />STATISTICAL INVENTORY RECONCILATION (SIR) REPORT <br />}FF,rUnocal No. <br />4409 <br />12000 <br />Leak <br />Threshold <br />gph <br />0.20 <br />This Month <br />Minimum Calculated <br />Detectable Leak Rate (6b) <br />Leak Rate (6c) <br />gph gph <br />0.20 -0.11 <br />Pass, Fall, <br />Inconclusive <br />P F I <br />` <br />Last <br />Month (7) <br />Two <br />Months <br />Ago (7) <br />Stockton <br />lis U e� <br />P F 1 <br />PTF I <br />Tank No. 89-1 <br />1• <br />Name <br />Unocal <br />Not <br />Submitted <br />°wImperial <br />��Phone <br />Tank No. 92-1 <br />Premium Unleaded <br />12000 <br />0.20 <br />(714) 572-7653 <br />0.08 <br />Phona <br />(714) 572-7653ETL <br />Southwest <br />Phone <br />(602) 837-8738SIRAS <br />— version 2.8.3—PPM 3.2.209Date <br />of <br />SIR report 5/11/95is <br />the required number of usable inventory days per tank? 15 <br />Tank No. 87-1 <br />Regular Unleaded <br />12000 <br />Leak <br />Threshold <br />gph <br />0.20 <br />This Month <br />Minimum Calculated <br />Detectable Leak Rate (6b) <br />Leak Rate (6c) <br />gph gph <br />0.20 -0.11 <br />Pass, Fall, <br />Inconclusive <br />P F I <br />` <br />Last <br />Month (7) <br />Two <br />Months <br />Ago (7) <br />Pass, Fall, <br />Inconclusive <br />Pass, Fall, <br />Inconclusive <br />P F 1 <br />PTF I <br />Tank No. 89-1 <br />Medium Grade Unl6 <br />12000 <br />0.20 <br />Not <br />Submitted <br />Tank No. 92-1 <br />Premium Unleaded <br />12000 <br />0.20 <br />0.20 <br />0.08 <br />Tank No. DSL -1 <br />#2 Diesel Fuel <br />12000 <br />0.20 <br />0.20 <br />-0.12 <br />NOTE: N/A indicates No Analysis Performed <br />Negative Calculated Leak Rates indicate a Gain <br />1. The tank owner is required to have an SIR report for each month [Section 2643 (b)(3) CCR']. <br />2. Monthly reports must be submitted to the local agency upon request [Section 2712 (b) CCR]. <br />3. The tank owner is required to have the report by the 20th day of the following month [Section 2646.1 (c) CCR]. <br />4. If for any reason, the test is neither "pass" nor "fail", the "inconclusive column must be marked. <br />5. The local agency must be notified of a tank that does not pass the SIR test within 24 hours of receipt of <br />the report and the SIR report must be submitted to the local agency within 10 days of the date of the <br />report [Section 2646.1 (d) CCR]. <br />6. Quantitative and Qualitative Methods: <br />a. A leak threshold, minimum detectable leak rate, and calculated leak rate must be provided for each <br />tank. If not, then the tank failed the SIR test. <br />b. If the calculated leak rate for a tank is greater than or equal to the leak threshold, the tank failed the SIR test. <br />c. If the minimum detectable leak rate for a tank is greater than the certified performance standard (i.e., 0.1 or <br />0.2 gph) and the calculated leak rate is less than the leak threshold, the test is inconclusive for that month. <br />d. Two consecutive failures and/or inconclusives requires a tank and/or piping integrity test within 15 days <br />from the date of the second report [Section 2646.1 (h) CCR]. <br />7. Optional. <br />CCR means Title 23, Division 3, Chapter 16 of the California Code of Regulations <br />SWRCB— SIR/MON —01 (12/94) <br />