CALIFORNIA MONTHLY <br />STATISTICAL INVENTORY RECONCILATION (SIR) REPORT <br />1. The tank owner is required to have an SIR report for each month [Section 2643 (b)(3) CCR']. <br />2. Monthly reports must be submitted to the local agency upon request [Section 2712 (b) CCR]. <br />3. The tank owner is required to have the report by the 20th day of the following month [Section 2646.1 (c) CCR]. <br />4.. If for any reason, the test is neither "pass* nor'fail', the 'inconclusive column must be marked. <br />5. The local agency must be notified of a tank that does not pass the SIR test within 24 hours of receipt of <br />the report and the SIR report must be submitted to the local agency within 10 days of the date of the <br />report [Section 2646.1 (d) CCR]. <br />6. Quantitative and Qualitative Methods: <br />a. A leak threshold, minimum detectable leak rate, and calculated leak rate must be provided for each <br />tank If not, then the tank failed the SIR test. <br />b. If the calculated leak rate for a tank is greater than or equal to the leak threshold, the tank failed the SIR test. <br />c. K the minimum detectable leak rate for a tank is greater than the certified performance standard (i.e., 0.1 or <br />0.2 gph) and the calculated leak rate is less than the leak threshold, the test is inconclusive for that month. <br />d. Two consecutive failures and/or inconclusives requires a tank and/or piping integrity test within 15 days <br />from the date of the second report [Section 2646.1 (h) CCR]. <br />7. Optional. <br />Person conducting evaluation <br />Signature (optional) Date <br />' CCR means Title 23, Division 3, Chapter 16 of the Caliiomia Code of Regulations <br />SWRCB—SIRIMON-01 (12/94) <br />Unocal No. <br />Address <br />4409 <br />1502 N. EI Dorado <br />City Stockton <br />Phone <br />(714) 572-7653 <br />Zip 95204 <br />Name <br />Unocal <br />Address <br />City <br />2929 E. Imperial Highway <br />Brea <br />Phone (714) 572-7653 <br />NOPERATOR = Name <br />Unocal <br />Phone (714).,.572-7653 <br />ETL Southwest <br />Phone (602) 837-8738 <br />SIRAS —version SIRAS 2.8.3 —4D 3.1.1 <br />Date of SIR report 3/10/95 <br />2/95 <br />What is the required member of usable inventory days per tank? 15 <br />pTankNo. <br />"��'°•' _ <br />Leak <br />Threshold <br />gph <br />This Month <br />Minimum Calculated Pass, Fail, <br />Detectable Leak Rate (6b) Inconclusive <br />Leak Rate (sc) <br />gph gph P F I <br />Last <br />Month (7) <br />Two <br />Months <br />Ago (7) <br />Pass, Fail, <br />Inconclusive <br />P F I <br />Pass, Fail, <br />Inconclusive <br />P F 1 <br />-1 <br />Regular Unleaded <br />12000 0.20 <br />0.20 <br />-O.b2 <br />' <br />-1 <br />Medium Grade Unl <br />12000 0.20 <br />N/A <br />N/A <br />-1 <br />Premium Unleaded <br />12000 0.20 ' <br />0.20 <br />0.01 <br />' <br />Tank No. DSL -1 <br />#2 Diesel Fuel <br />120001 0.20 <br />1 0.20 <br />-0.06 <br />' <br />' <br />1. The tank owner is required to have an SIR report for each month [Section 2643 (b)(3) CCR']. <br />2. Monthly reports must be submitted to the local agency upon request [Section 2712 (b) CCR]. <br />3. The tank owner is required to have the report by the 20th day of the following month [Section 2646.1 (c) CCR]. <br />4.. If for any reason, the test is neither "pass* nor'fail', the 'inconclusive column must be marked. <br />5. The local agency must be notified of a tank that does not pass the SIR test within 24 hours of receipt of <br />the report and the SIR report must be submitted to the local agency within 10 days of the date of the <br />report [Section 2646.1 (d) CCR]. <br />6. Quantitative and Qualitative Methods: <br />a. A leak threshold, minimum detectable leak rate, and calculated leak rate must be provided for each <br />tank If not, then the tank failed the SIR test. <br />b. If the calculated leak rate for a tank is greater than or equal to the leak threshold, the tank failed the SIR test. <br />c. K the minimum detectable leak rate for a tank is greater than the certified performance standard (i.e., 0.1 or <br />0.2 gph) and the calculated leak rate is less than the leak threshold, the test is inconclusive for that month. <br />d. Two consecutive failures and/or inconclusives requires a tank and/or piping integrity test within 15 days <br />from the date of the second report [Section 2646.1 (h) CCR]. <br />7. Optional. <br />Person conducting evaluation <br />Signature (optional) Date <br />' CCR means Title 23, Division 3, Chapter 16 of the Caliiomia Code of Regulations <br />SWRCB—SIRIMON-01 (12/94) <br />