My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
430
>
2300 - Underground Storage Tank Program
>
PR0232369
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 9:32:56 AM
Creation date
11/4/2018 4:15:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232369
PE
2381
FACILITY_ID
FA0003975
FACILITY_NAME
SKEETERS AUTO TRANSMISSIONS
STREET_NUMBER
430
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14906413
CURRENT_STATUS
02
SITE_LOCATION
430 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\430\PR0232369\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
11/21/2012 8:00:00 AM
QuestysRecordID
74161
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNif WATER RESOURCES CONTROT OARD <br /> FORM 'B': UNDER"bROUND STORAGE TANK PROMAM Y w <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWINq INFORMATION FOR EACH TANK. - - Z <br /> IO <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWALPERMIT CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANI( <br /> ONE ITEM 2 INTERIM PERMIT El AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED �� w <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: I , S k# ARM TANK-YES❑ NO ❑ <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> A. OWNERSTANKIDN I I B. MANUFACTURED B <br /> C. YEAR INSTALLED U D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUMC. ❑ 1 UNLEADED 2 LEADED ❑ 3 DIESEL <br /> F-13 CHEMICAL PRODUCT F7B.4 OIL ;?,/PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.W <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,8 D <br /> A.TYPE OF 1:11 DOUBLE WALLED ❑3 SINGLE WALLED WITH BlERIOR UNER ❑ 95 UNKNOWN <br /> SYSTEM ffe'SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEELARON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑6 POLYVINYL CHLORIDE [W:] 7 LUMINUM ❑8 180%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEELUNKNOWN ❑99 OTHER <br /> C. INTERIOR F-1I RUBBER LINE ❑2 ALKYD LINING ❑3 EPDXY LINING ❑ HENOUC LINING <br /> LINING F-15 GLASS LINING ❑6 UNUNED UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NOOTHER ()h <br /> D. CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TAR OR ASPHALT ❑ 3 VA WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE E114UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IFABOVEGROUND, U IF UNDERGROUND,130TH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE U 95 UNKNOWN A U 99 OTHER II <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FlBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5ALUMINUM A SCONCRETE A U 7STEELCLADW/FRP A U 8100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> Il 8 1 VISUALCHECK 6 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> L./ P 8 6 PRECISION TESTING P 8 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES [:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPUrANTS NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> 316 1yj I ol ol ol 3 <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> L <br /> PERMIT NUMBER PERMIT APP RO AL DA PERMIT EXPIRATION DATE <br /> Z Z/ fjg <br /> CHECK# PERMIT AMOUNT I SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORM B 7 19-691 THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br />
The URL can be used to link to this page
Your browser does not support the video tag.