My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 1998-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:31:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2004
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 1998-2004.PDF
QuestysFileName
COMPLIANCE INFO 1998-2004
QuestysRecordDate
5/19/2017 4:43:15 PM
QuestysRecordID
3389407
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDER OUND STORAGE TANKS ANK PAGE 2 TANK <br /> A.PIPING CONSTRUCTION(Check all that apply) Page_ or <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ®1.PRESSURE ❑2 SUCTION ❑3.GRAVITY 458 ❑1.PRESSURE - ❑2. SUCTION ❑3.GRAVITY 459 <br /> CONSTRUCTION/ ❑1.SINGLE WALL ❑3.LINED TRENCH ❑99.OTHER 460 ❑1.SINGLE WALL ❑95.UNKNOWN 462 <br /> MANUFACTURER 02.DOUBLE WALL ❑95.UNKNOWN ❑2.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER TelefleX 461 MANUFACTURER 963 <br /> ❑1.BARE STEEL ®6.FRP COMPATIBLE w1100% METHANOL ❑1.BARE STEEL ❑6.FRP COMPATIBLE yinom METHANOL <br /> ❑2 STAINLESS STEEL ❑7.GALVANIZED STEEL ❑UKNOWN ❑2. STAINLESS STEEL ❑7.GALVANIZED STEEL <br /> ❑3.PLASTIC COMPATIBLE W/CONTENTS ❑99. OTHER ❑3. PLASTIC COMPATIBLE W/CONTENTS ❑8.FLEXIBLE(HDPE) ❑99. OTHER <br /> ❑4.FIBERGLASS ❑8.FLEXIBLE(HOPE) 0 4. FIBERGLASS 0 9.CATHODIC PROTECTION - <br /> ❑S.STEEL W/COATING ❑9.CATHODIC PROTECTION 464 ❑5. STEEL WICOATING ❑95.UNKNOWN 465 <br /> VII.PIPING LEAK DETECTION Check all Nat apply)(A description of the monitoring program shall be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑1. ELECTRONIC UNE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR <br /> LEAK SYSTEM FAILURE,AND SYSTEM DISCONNECTION*AUDIBLE AND VISUAL LEAK SYSTEM FAILURE,AND SYSTEM DISCONNECTION.AUDIBLE AND VISUAL <br /> ALARMS. ALARMS. <br /> ❑2. MONTHLY 0.2 GPH TEST ❑2. MONTHLY 0.2 GPH TEST <br /> 03. ANNUAL INTEGRITY TEST(O.1GPH) 03. ANNUAL INTEGRITY TEST(0.1GPH) <br /> ❑4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check ad Nztapply) <br /> 135. DAILY VISUAL MONITORING OF PUMPING SYSTEM.TRIENNIAL PIPING INTEGRITY <br /> TEST(0.1 GPH) [35. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): 06. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> ❑7. SELF MONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW ❑7. SELF MONITORING <br /> ❑9. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Chad all Natapply): <br /> 08. DAILY VISUAL MONITORING <br /> ❑9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check ail that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE ANDVISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br /> (Check ore) (Chick one) <br /> ❑a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑b AUTO PUMP SHUT OFF FOR LEAKS.SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> Sc. NOAUTO PUMP SHUT OFF ❑c NOAUTOPUMPSHUTOFF <br /> 011. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) LTH FLOW SHUTOFF OR <br /> RESTRICTION 011. AUTOMATIC LEAK DETECTOR <br /> ®12. ANNUAL INTEGRITY TEST(0.1 GPH) ❑12. ANNUAL INTEGRITY TEST(0.1 GPA) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> 013. CONTINUOUS SUMP SENSOR-AUDIBLE AND VISUAL ALARMS 013. CONTINUOUS SUMP SENSOR.AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑14. CONTINUOUS SUMP SENSOR WITHOUT ALTO PUMP SHUT OFF.AUDIBLE AND 014. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF.AUDIBLE AND <br /> VISUALALARMS VISUALALARMS <br /> ❑15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR 15. AUTOMATIC LINE LEAK DETECTOR 3 0 GPH TES <br /> RESTRICTION ( T) <br /> [116. ANNUAL INTEGRITY TEST(0.1 GPH) ❑16. ANNUAL INTEGRITY TEST 10.1 GPH) <br /> ❑17. DAILY VISUAL CHECK ❑17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER ®1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE <br /> CONTAINMENT ❑4.DAILY VISUAL CHECK <br /> DATEINSTALLED 466 ❑2. CONTINUOUS DISPENSER PAN SENSOR.AUDIBLE AND VISUAL ALARMS ❑5.TRENCH LINER I MONITORING <br /> 1998 ❑3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER. �6.NONE 469 <br /> AUDIBLE ANDVISUAL ALARMS <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I wrlify that the inrormatio pro dad hereis" n aerate to the bast of my knowledge. <br /> SIGNATURE E R DATE 470 <br /> 1/25/02 <br /> NAM EOFOWNERIOPRATOR(pdnt) TITLE OF OWNER/OPERATOR 472 <br /> Dennis Smith Operations & Environmental Specialist <br /> Permit Number(For local use only) 473 Permit Approved(Far[owl use only) Permit Expiration Data(For local use only) <br /> 475 <br /> UPCF(1/99 revised) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.