My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 1998-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:31:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2004
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 1998-2004.PDF
QuestysFileName
COMPLIANCE INFO 1998-2004
QuestysRecordDate
5/19/2017 4:43:15 PM
QuestysRecordID
3389407
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DATE <br /> SAN JOAQUIN COUNTY PR# <br /> 6VIRONMENTAL HEALTH DEPAR NT PAGE <br /> 304 E.Weber Ave.,Third Floor, Stockton, CA 5202 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility Name VMZ �i0 Facility Address i✓. <br /> Facilty Contact h�r-ZW -&j&-entitle (_SE- Phone #5_7Z� <br /> UST# Product Ul✓ UST#•9Product U1--UST#Product l 1, UST#_Product <br /> Overfill Prevention: X,AudibleNisual O Mechanical Monitoring Panel: <br /> Piping System: D Gravity )Q Pressure D Suction Violations: Minor O Major <br /> Automatic Pum Shut D wn Sati fies CCR 2636 D Yes No Dispenser Pan: D Yes No <br /> INSPECTION TYPE: outine Wonitoring Certification OComplaint Dlnstall ORemoval ❑Repair/Upgrade <br /> COMPANY NAME: TECHNICIAN NAME: PHONE: aO -01 <br /> - N01-OEe VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> 1 HSC 25284 Permit to operate 20 CCR 2712 (b) Maintenance & monitoring <br /> 2 CCR 2637 Secondary cont testing (6 records <br /> month/36 month) 21_y/_CCR 2636 (f)(4) Annual line tightness test <br /> 3 CCR 2711(b)& (c) Current State Forms A& B 22 CCR 2630 (d) Annual line leak detector test <br /> 4=HSC 25292.2 Certification of financial 23 CCR 2630 (d) Annual monitoring certification <br /> responsibility and letter from 24 CCR 2643 (d) Daily monitoring of suction <br /> chief financial officer piping that is not continuously <br /> 5 CCR 2630 (d) Continuous monitoring system monitored <br /> for UST system 25 CCR 2636 (a) Conventional suction piping <br /> 6 CCR 2636 (c)(1) All releases in secondary piping shall have continuous <br /> flow to a collection sump monitoring &20 containment <br /> 7 HSC 25291 (e) Water in secondary (20)cont 26 CCR 2643 (e) Biennial tightness test of gravity <br /> 8 HSC 25291 (f) Automatic line leak detector(s) piping that is not continuously <br /> 9 CCR 2636 (f)(1) Continuous monitoring system monitored <br /> for underground piping 27 CCR 2662 Upgrade requirements for UST <br /> 10 CCR 2632 (c)(2) Continuous monitoring system system <br /> for UST 28 CCR 2661 Permit to repair UST system <br /> 11 HSC 25291(a)(2) Secondary containment for 29 HSC 25286 (a) Permit to alter monitoring <br /> UST is tight system <br /> 12 CCR 2636 (f)(1) Continuous monitoring system 30HSC 25298 (a) Illegal abandonment of UST <br /> for dispenser system system <br /> 13__,,/ CCR 2635 (b)(1) Spill container 31 HSC 25298 (b) Permit to temporarily close UST <br /> 14 CCR 2635(b)(2) Overfill prevention system system <br /> 15 CCR 2631 (a) Primary containment is product- 32 HSC 25298 (c) Permit to close UST system <br /> tight 33 HSC 25291 (e) Water in 20 cont analyzed and <br /> 16 HSC 25292.1 UST system is operated to properly disposed of <br /> prevent unauthorized release 34 CCR 2640 (e) Single wall component within <br /> 17 CCR 2650 Recording/reporting 1 000'of Public Well, no ELD <br /> / unauthorized release 35 CCR 2635(a)(2)(A)Cathodic protection testing <br /> 18 V CCR 2632 (d) Monitoring & response plan 36 H&SC 25299(a)(9)Disabling leak detect. devices <br /> 19— CCR 2712 (i) Monitoring & response plan is 37 Violation(s)not listed above <br /> on site g <br /> EHD INSPECTOR: PHONE: ' f7 <br /> RECEIVED BY: TITLE: <br /> UNITII W ST/INSP(rev 726102) <br />
The URL can be used to link to this page
Your browser does not support the video tag.