COMPLIANCE INFO 1998-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 1998-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:31:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2004
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 1998-2004.PDF
QuestysFileName
COMPLIANCE INFO 1998-2004
QuestysRecordDate
5/19/2017 4:43:15 PM
QuestysRecordID
3389407
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Alitoring System Certification <br />Site Address: 153E 11TH ST <br />F. In -Tank Gauging / SIR Equipment <br />• <br />Date of Testing/Service: 02/10/2004 <br />M Check this box if tank gauging is used only for inventory control. <br />❑ Check this box if no tank gauging or SIR equipment is installed. <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. <br />Complete the following checklist: <br />0 Yes <br />1:1 No • <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />QYes <br />❑No' <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />❑ Yes <br />❑No' <br />Was accuracy of system product level readings tested? <br />❑Yes <br />❑No • <br />Was accuracy of system water level readings tested? <br />❑x Yes <br />❑No • <br />Were all probes reinstalled property? <br />❑ Yes <br />❑No ` <br />Were all items on the equipment manufacturers' maintenance checklist completed? <br />` In the Section H, below, describe how and when these deficiencies were or will be corrected. <br />G. Line Leak Detectors (LLD) : ❑ Check this box if LLDs are not installed. <br />Comnlete the following checklist: <br />Q Yes <br />❑ No' <br />E] NIA <br />For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? <br />(Check all that apply) Simulated leak rate: X❑ 3 g.p.h ❑ 0.1 g.p.h ❑0.2 g.p.h <br />X Yes <br />❑ No ` <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />M Yes <br />❑No • <br />Was the testing apparatus properly calibrated? <br />FX Yes <br />❑No • <br />❑ N/A <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />❑ Yes <br />❑No • <br />❑X N/A <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />❑ Yes <br />[—]No ` <br />j M N/A <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? <br />❑ Yes <br />❑No ` <br />❑X N/A <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? <br />❑ Yes <br />❑No' <br />❑X N/A <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />❑ Yes <br />❑No ` <br />Were all items on the equipment manufacturers' maintenance checklist completed? <br />' In the Section H. below, describe how and when these deficiencies were or will be corrected. <br />H. Comments: <br />Page 3 of 3 Based on CA form dated 03/01 <br />