Laserfiche WebLink
CAS VESSEL FOOTING <br /> 6" MIN.— _15' MAX.— <br /> SL <br /> 7.1 <br /> EXISTING <br /> CONCRETE <br /> DRIVE SLAB <br /> (TYPI) <br /> DOWL NEW REBARJ <br /> #4 0 2' O.C. <br /> 02' EACH SIDE OF TRENCH <br /> 2e MIN. <br /> OR EXISTING <br /> NATIVE— CONDUIT DEPTH <br /> SOIL <br /> 28.5" 0 <br /> BASE <br /> 28,5*10— 3/4"0 4 HOLES— 3'-6- <br /> ON 32* 0 B.C. <br /> TOC <br /> 5/0'a" HILTS KWIK BOLT TZ STAINLESS <br /> 3/4- CHAIMFER '. ".' <br /> L,,PTEEL 04" EMBEDMENT MIN. (4-PLACES) <br /> 8 SAN • 3 MIN, <br /> FINISH GRADE <br /> 8". MIN. -6- —3- 6- 3/4" RIGID ELECTRICAL CONDUIT w/ LOW— <br /> ]�CLR VVOLTAGE INTRINSICALLY SAFE 3-WIRE <br /> 3* MIN. <br /> 7'-0' SHIELDED CABLE (N) CONNECT TO EXISTING <br /> 3`-6" <br /> 3/4" RIGID coNDUIT USING FEMALE UNION <br /> —7.-o 3" CLR (TYP-) CRITERIA ELECTRICAL CONNECTION (KILLARK UNF) <br /> A <br /> MIN: CONCRETE COMP STRENGTH, 6 = 2500pal:#4 EACH WAY TYP. 01 a" D.C. MN. REINF. YIELD STRENGTH, fy = 40D00 pet <br /> CLEAN AIR-SEPARATOB SLAB ELECTRICAL CONDUIT TRENCH SECTION A-A <br /> NOT TO SCALE NOT TO SCALE <br /> BUILDING INSPECTOR&ONTRAGER NOTE <br /> • CORROSION PROTECTION/WRAPPING ARE REQUIRED ON ALL UNDER-SLAB FERROUS ELECTRICAL CONDUIT, <br /> EXISTING VENT RACK 11' PIPE GALVANIZED, WATER PIPING, BUILDING DRAINS, BUILDING SEWERS, FLOOR SINKS, FLOOR DRAINS, TRAP PRIMERS, WASTE <br /> AND 2' VENT LINES 1/8' PER FOOT PITCH DRAINS, AND OTHER FERROUS PIPING, INCLUDING ALL ZINC-COATED GALVANIZED PIPING AND FITTINGS. <br /> TOWARD V€N7 <br /> • CORROSION PROTECTION/WRAPPING ARE REQUIRED ON COPPER WATER PIPING (PER C.O.T. MUNICIPAL CODE <br /> 1. ALL BALL VALVES (B.V.) TO BE AND THE 2007 CPC, SEC. 313.5). <br /> UL LISTED AND HAVE PADLOCK . CORROSION PROTECTION SHALL BE INSPECTED AND APPROVED BY THE BUILDING INSPECTOR BEFORE <br /> FEATURE COVERING. <br /> 2. PASSIVE PRESSURE <br /> CONTROL-NO ELECTRICAL <br /> POWER REQUIRED. <br /> 3. ONLY GALVANIZED PIPE IS TO <br /> BE USED FOR PIPING <br /> CONNECTIONS. <br /> FIGURE 2 <br /> PHASE II EVR <br /> DETAILS <br /> ULTRAMAR STATION No.3698 <br /> 153 EAST 11TH STREET <br /> TRACY,CALIFORNIA <br /> SHEET 2 OF 3 <br /> PREPARED BY: REVIEWED BY: <br /> Bo LL VALVE 104" REF. J. OCKER C. YORK <br /> (TYPICAL) DATF1 8/21/08 DATE: 0/22/08 <br /> DRAWING No: <br /> FIGURE 2 <br /> —CLEAN AIR SEPARATOR (CAS) PROJECT No; <br /> (.36' O.D. x 90 LG.) AS600 <br /> FILENAME: <br /> AS600-3698-153 E 11th St Tracy MAILS w ENC.dwg <br /> _�—CAS SLAB <br /> GROUND SURFACE <br /> CLEAN AIR SEPARATOR INSTALLATION <br /> NOT TO SCALE <br />