My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2005-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:32:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2011
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2005-2011.PDF
QuestysFileName
COMPLIANCE INFO 2005-2011
QuestysRecordDate
5/19/2017 6:00:47 PM
QuestysRecordID
3389699
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
372
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> i Tanknology <br /> TEST DATE:02/10/09 8501 N MOPAC EXPRESSWAY,SUITE 400 <br /> CLIENT:VALERO AUSTIN,TEXAS 78759(512)451-6334 WORK ORDER NUMBER2263498 <br /> SITE:ULTRAMAR 3698 (VALERO) <br /> . T/1NWJNF:RN1AT10N r. ryna <br /> rMaterial: <br /> ID: #3 1 Tank manifolded: No <br /> Bottom t0 top fill In inches: 133.5 <br /> ct: SUPREME Vent manifolded: YES Bottom to grade in inches: 141.o <br /> ns: 10,152 Vapor recovery manifolded: YEs <br /> s: 96.00 Fill pipe length in inches: 37.5 <br /> Overfill protection: YES Fill pipe diameter in inches: 4.o <br /> s: 328 Overspill protection: YES Stage I vapor recovery: DUAL <br /> ial: DW STEEL Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> .TANK TEST RESULTS Test Method:VacuTect' L" LEAK.DETECTOR TEST RESULTS t" <br /> + ^rest method: FTA al' <br /> Start(in) End(in) <br /> Dipped Water Level: New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: Make: RED JACKET <br /> Ingress Detected: Water Bubble Ullage Model: Fx1V <br /> Test time: S/N: 4578 <br /> Inclinometer reading: Open time in sec: 4.00 <br /> VacuTect Test Type: NOT Holding psi: 20 <br /> VacuTect Probe Entry Point: TESTED Resiliency cc: 80 NOT <br /> Pressure Set Point: Test leak rate ml/m: 189.0 TESTED <br /> Tank water level in inches: Metering psi: 8 <br /> Water table depth in inches: Calib. leak in gph: 3.00Results: PASS <br /> Determined by(method): <br /> Result: <br /> COMMENTS <br /> OMMENTS <br /> 7DiamRE <br /> IN <br /> eter <br /> l: DW FIBERG <br /> : 2,0 <br /> : 150.0 <br /> : 50 <br /> 7 accc: 5 <br /> Test time(min): 30 NOT <br /> Start time: 12:00 NOT NOT <br /> TESTED TESTED TESTED <br /> End time: 12:30 <br /> Final gph: 0.000 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: RED JACKET <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 02/20/2009 09:06 <br />