My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2005-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:32:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2011
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2005-2011.PDF
QuestysFileName
COMPLIANCE INFO 2005-2011
QuestysRecordDate
5/19/2017 6:00:47 PM
QuestysRecordID
3389699
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
372
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. Piping Sump Testing <br /> Test Method Developed By: ❑Tank Manufacturer Z Industry Standard El Professional Engineer <br /> Test Method Used: ❑ Pressure <br /> ❑Vacuum N Hydrostatic <br /> Test Equipment Used: Incon TS STS Leak Detector Equipment Resolution:±0.002 <br /> Sump# 87A Sump# 87B Sump# 91 Sump# <br /> Sump Diameter: 48" 48„ 48" <br /> Sump Depth: 32" 31" 31" <br /> Sump Material: Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: 27" 27" 27" <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: 19„ 24" 24„ <br /> Condition of sump prior to testing: ok <br /> ok ok <br /> Potion of Sump Tested 100% 100% 100% <br /> Does turbine shut down when <br /> sump sensor detects liquid(both 0 Yes 0 No ® NA 0 Yes 0 No 0 NA 0 Yes 0 No ® NA 0 Yes 0 No 0 NA <br /> product and water)?* <br /> Turbine shutdown response time N/A N/A N/A <br /> Is system programmed for fail-safe <br /> shutdown?' 0 Yes 0 No 0 NA 0 Yes 0 No ® NA 0 Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> Was fail-safe verified to be <br /> operational?' 0 Yes 0 No ®NA Oyes ONO ® NA 0 Yes 0 No ®NA 0 Yes 0 No 0 NA <br /> Wait time: 15 min 15 min 15 min <br /> Test Start Time: 11:53 am 11:53 am 12:22 pro <br /> Initial Reading: 1,9928 22796 42871 <br /> Test End Time: 12:09 pm 12:09 pm 12:37 pm <br /> Final Reading: 1.9929 2.2798 4.2889 <br /> Test Duration(hh:mm): 00:16 E00:116 - 00:15 00:00 <br /> Change in Reading: 0.0001 0002 0.0018 <br /> 0.0000 <br /> Pass/Fail Threshold or Criteria: ±0.002 ±0.002 ±0.002 ±0.002 <br /> ,T60tResult:'. ` # Pass 0 Fail #Pass 0 Fail * Pass 0 Fail I DPass 0 Fail <br /> - —�-- — <br /> Was sensor removed for testing? DQ Yes 0 No 0 NA Yes 0 No 0 NA t] Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> Was sensor properly replaced and ®Yes 0 No 0 NA Yes 0 No 0 NA ®Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> verified functional after testing? <br /> Comments: <br /> 4 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.