COMPLIANCE INFO 2005-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2005-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:32:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2011
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2005-2011.PDF
QuestysFileName
COMPLIANCE INFO 2005-2011
QuestysRecordDate
5/19/2017 6:00:47 PM
QuestysRecordID
3389699
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
372
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> riâ–ºTanknology <br /> TEST DATE:02/08/11 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER2 2 7 9 3 6 5 <br /> CLIENT:VALERO AUSTIN,TEXAS 78759(512)451-6334 SITE:VALERO 3698 <br /> IIIIIIIIIINK - TANK INFORMATJ <br /> Tank ID: 3 Tank manifolded: NO Bottom to top fill in inches: 137.0 <br /> Product: PREMIUM Vent manifolded: YES Bottom to grade in inches: 144.0 <br /> Capacity in gallons: 10,152 Vapor recovery manifolded: YES Fill pipe length in inches: 41.0 <br /> Diameter in inches: 96.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 328 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW STEEL Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> ANK TEST RESULTS Test Method:VacuTect `LEAK DETECTOR TEST RESULTS 1.W`Test method: LDT-5000 <br /> Start(in) End(in) <br /> Dipped Water Level: New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: Make: RED JACKET <br /> Ingress Detected: Water Bubble Ullage Model: Fxly <br /> S/N: 18]8 <br /> Test time: <br /> IOpen time in sec: 2.00 <br /> Inclinometer reading: <br /> Holding psi: 22 <br /> VacuTect Test Type: NOT Resiliency cc: so NOT <br /> VacuTect Probe Entry Point: TESTED Test leak rate ml/m: 189.0 TESTED <br /> Pressure Set Point: Metering Psi: to <br /> Tank water level in inches: Calib. leak in gph: 3.00 <br /> Water table depth in inches: Results: PASS <br /> Determined by(method): <br /> Result: <br /> COMMENTS <br /> COMMENTS <br /> LINE TEST RESULTS <br /> Ua._. <br /> Material: DW FIBERG <br /> Diameter(in): 2.0 <br /> Length (ft): 150.0 <br /> Test psi: 50 <br /> Bleedback cc: 41 <br /> Test time(min): 30 NOT NOT NOT <br /> Start time: 10:35 TESTED TESTED TESTED <br /> End time: 11:05 <br /> Final gph: 0.003 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: RED JACKET <br /> L <br /> TS Impact Valves Operational: YES <br /> Printed 02/16/2011 08:33 <br />