My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2005-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:32:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2011
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2005-2011.PDF
QuestysFileName
COMPLIANCE INFO 2005-2011
QuestysRecordDate
5/19/2017 6:00:47 PM
QuestysRecordID
3389699
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
372
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> iâ–ºTanknology <br /> TEST DATE:02/06/07 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER2247169 <br /> CLIENT:VALERD AUSTIN,TEXAS 78759(512)451-6334 SITE:ULTRAMAR 3698 (VALERO) <br /> TANK INFORMATION= ' ... .. .. <br /> Tank ID: #3 1 Tank manifolded: No Bottom to top fill in inches: 133.5 <br /> Product: SUPREME Vent manifolded: YES Bottom to grade in inches: 141.0 <br /> Capacity in gallons: 10,152 Vapor recovery manifolded: YES Fill pipe length in inches: 37.5 <br /> Diameter in inches: 96.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 328 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW STEEL Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> TANK TEST RESULTS Test Method:vacuTect LEAK DETECTOR TEST RESULTS Test method: FTA <br /> Start(in) End (in) <br /> Dipped Water Level: New/passed Failed/replaced Need Failed/replaced <br /> L.D.#t <br /> L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Dipped Product Level: <br /> Probe Water Level: Make: RED JACKET RED JACKET <br /> Ingress Detected: Water Bubble Ullage Model: FK1V FK1V <br /> 2020 <br /> 6-4578 <br /> time: Open time in sec: 2. 000 40304-2401 <br /> Inclinometer reading: Holding psi: 20 <br /> VacuTect Test Type: NOT Resiliency cc: 140 NOT <br /> VacuTect Probe Entry Point: TESTED Test leak rate ml/m: 189.0 TESTED <br /> Pressure Set Point: Metering psi: 12 <br /> Tank water level in inches: Calib. leak in gph: 3.00 3.00 <br /> Water table depth in inches: Results: PASS FAIL <br /> Determined by(method): <br /> Result: COMMENTS <br /> COMMENTS <br /> LINE TEST RESULTS .est type:. TLD- <br /> LINE <br /> &..:..,. ':;.0 <br /> Material: DN FIBERG <br /> Diameter(in): 2.0 <br /> Length (ft): 150.0 <br /> Test psi: 50 <br /> Bleedback cc: 60 <br /> Test time(min): 60 NOT NOT NOT <br /> Start time: 11:10 TESTED TESTED TESTED <br /> End time: 12:10 <br /> Final gph: 0.006 <br /> Result: BASS <br /> Pump type: PRESSURE <br /> Pump make: RED JACKET <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 02/12/2007 08:55 <br />