Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> e By All Jurisdictions IMlhin the State of Califomi <br /> Authority Cited:Chapter 6.7, and Safety Code;Chapter 16,Division 3 Title 23, mia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this forth to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: ULTRAMAR 3698(VALERO) City: TRACY CA Zip:95376 <br /> Site Address: 153E 11TH ST Contact Phone No: 832-8815 <br /> QC-D-3 Date of Testing/Service: 02/06/2007 <br /> Facility Contact Person: MGR-CHELA <br /> Make/Model of Monitoring System:V/R TLS 350 Work Order Number: 2247169 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: REG-1 Tank ID: REG-2 <br /> X In-Tank Gauging Probe. Model: MAG-1 X In-Tank Gauging Probe. Model: MAG-1 <br /> X Annular Space or Vault Sensor. Model: 420 Annular Space or Vault Sensor. Model: 420 <br /> -571 Piping Sump/Trench Sensor(s). Model: 206 Piping Sump/rrench Sensor(s). Model: 206 <br /> -371 <br /> Fill Sump Sensor(s). Model: 206 Fill Sump Sensor(s). Model: 206 <br /> X Mechanical Line Leak Detector. Model: FX1 V Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> )( Tank Overfill/High-Level Sensor. Model: ANNUNCIATOR Tank OvefiNHigh-Level Sensor. Model: ANNUNCIATOR <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: Tank ID: <br /> In-Tank Gauging Probe. Model: MAG-1 In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 420 Annular Space or Vault Sensor. Model: <br /> X Piping Sump/Trench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: <br /> jFill Sump Sensor(s). Model: 208 Fill Sump Sensor(s). Model: <br /> X Mechanical Line Leak Detector. Model: FX1V Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: ANNUNCIATOR Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser 1/2 Dispenser ID: 3/4 <br /> ❑Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s) Model: <br /> TJ Shear Valve(s). X Shear Valve(s) <br /> [X Dispenser Containment Float(s)and Chain(s). X Dispenser Containment Floats)and Chain(s). <br /> DispenserlD: 5/6 Dispenser ID: <br /> ❑Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> X] Shear Valve(s). Shear Valve(s). <br /> X Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shearvalve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment Identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports, I have also attached <br /> a copy of the(Check all that apply): System set-up X❑Alarm history report <br /> Technician Name(print): HEATH MCEVER Signature: <br /> Certification No.: A27562 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)8004633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 02/06/2007 <br /> Page 1 of 3 Based on CA form dated 03/01 <br /> Monitoring System Certification <br />