My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2005-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:32:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2011
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2005-2011.PDF
QuestysFileName
COMPLIANCE INFO 2005-2011
QuestysRecordDate
5/19/2017 6:00:47 PM
QuestysRecordID
3389699
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
372
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l0nitoring System Certification • <br /> Site Address 1 153 E 11TH ST Date of Testing/Service: 02/09/2010 <br /> QC-D-3 <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 17.01 <br /> Complete the following checklist: <br /> X Yes No. Is the audible alarm operational? <br /> Q Yes No• Is the visual alarm operational? <br /> ❑X Yes No• Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not <br /> Q Yes ❑No' interfere with their proper operation? <br /> Yes No• x N/A If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> ❑x Yes ❑No' ❑N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? <br /> IfDispensers:whichConsensors <br /> inensonitiate rsosifive <br /> shut-down?(check all that apply) Ox Sump(rrench Sensors; <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnecfion? ❑x Yes No <br /> EYes N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.:no mechanical <br /> ❑ ❑No• ❑ overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill points(s)and operating <br /> propedy. If so,at what percent of tank capacity does the alarm trigger? 90 <br /> ❑ Yes* ❑x No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,belowry y y) ❑ <br /> Product; <br /> ❑ Yes' ❑x No Was liquid found inside any secondary containment systems desi ned as d ppI <br /> ❑ Water. If yes,describe causes in Section E,below. <br /> ❑X Yes ❑No• Was monitoring system set-up reviewed to ensure proper settings?Attach set-up reports,if applicable. <br /> ❑ Yes ❑No• Is all monitoring equipment operational per manufacturers'specifications? <br /> .In Section E below,describe how and when these defrciences were or will be corrected. <br /> E. Comments: <br /> Page 2 of 3 Based on CA form dated 03/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.