My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:35:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2012-2015.PDF
QuestysFileName
COMPLIANCE INFO 2012-2015
QuestysRecordDate
5/19/2017 9:21:29 PM
QuestysRecordID
3390491
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s0qov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Valero Corner Store # Address:3698 Facility <br /> Name: 153 E. 11 th St. Tracy, CA 95376 Da1O0 Feb 6, 2013 <br /> VIOLATIONS <br /> # C7 C2 M Code Section HSC=CA Health and Sal Code;CFR=Code of Federal Regulations <br /> Cl=Class 1 Notation;C2=Class 2 vitiation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (Mi) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (Mt) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Reporr'for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS Ii,or MINOR-Notice to Comply) <br /> On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br /> 109. Annual monitoring system certification, leak detector testing, and spill container testing was <br /> performed on February 15, 2012, and a test report was not received within thirty days by the EHD. The <br /> test report was received on April 5, 2012, almost two months late. A copy of the test report must be <br /> submitted within 30 days of the tests. Take the necessary precautions that a copy of the test report is <br /> submitted to the EHD within thirty days of the test. <br /> 204. The designated operator failed to check and note the correct test dates for the spill container test <br /> on the August 2012 through January 2013 designated operator monthly inspection reports. These <br /> reports listed the spill container test as July 5, 2012. It should have been listed as July 11, 2012. During <br /> the monthly inspection, the designated operator shall check that all required testing and maintenance for <br /> the UST system have been completed and document the dates they were done. Ensure that designated <br /> operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. <br /> 303. The 91 turbine sump sensor was raised approximately three inches off the lowest point of the sump <br /> part way up the saddle of the sump bottom and not located to detect a leak at the earliest opportunity. <br /> Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. <br /> During the inspection, the technician relocated this sensor to the lowest point of the 91 turbine sump. <br /> Continue to ensure that the monitoring system sensors are properly located to detect a leak at the <br /> earliest opportunity. <br /> 305. The 87 and 91 Bravo box floats and chains in the UDC#3/4 & 5/6 sumps failed to stop the flow of <br /> product at the dispenser when tested. All monitoring equipment shall be maintained to activate an <br /> audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. The service <br /> technician adjusted the chains and verified functionality. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> Inspector .. Ivetl By� T <br /> EHD 2302 Rev 04/19/12 Page 3 ,MI'Q,,r•/ UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.