A
<br /> SAN JOAQUINPLOUNTY ENVIRONMENTAL HEALTHPARTMENT
<br /> 304 E.Weber Ave.,Third Floor•Stocl ton,CA 95202-2708•Phone(209)468-3420
<br /> Donna Heran,REH.S.,Director
<br /> ENVIRONMENTAL HEALTH
<br /> SAN JOAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY
<br /> PERMIT TO OPERATE
<br /> Program Permit - Permit
<br /> Record ID Number Program Code and Description Valid
<br /> PR0518465 PT0012038 2220-SMALL QUANTITY HAZARDOUS WASTE GENERATOR.FACILITY 1/1/2007 To 12/31/2007
<br /> Hazardous Waste Generator Program:
<br /> In order to maintain the per operate,Hazardous Waste Generators.shall.comply with California.Health and Safety Code,Div.20,Chap.6.5,Art.2-13,
<br /> Sec.25100 et seq,and Tit _22,C ifornia Code of Regulations,Chap.20,-__.__--_-__--_-____---___-----.______._.___..._.___c.----._.-__-----------------
<br /> PR0231389 2300• NDERGROUND STORAGE TANK FACILITY 1/1/2007 To 12/3112007
<br /> Under round Stora a Ta to ram: -
<br /> California Health and Safe ode,Div 20,Cha:6.7 and Title 23,California Code of Regulations,Chap, 16_ :------____ _-----_-.
<br /> ----- -- - -- ---------p - - - -------- ----- - ----
<br /> P/E Tank N Tank R o dD Permit# Capacity Contents Permit Status System Type - Leak Detection -
<br /> - 2362 4 39000231389 1 9 PTOOD423U 10,000 REGULAR UNLEADED Active,billable DOUBLE WALLED' Continuous Interstitial Monitoring
<br /> 2360 5 39000231--- 3805 PT0004237 10,000 REGULAR UNLEADED Active,billable DOUBLE WALLED- continuous Interstitial Monitoring
<br /> 2360 6 390002313890138906 PT0004239 10,000 PREMIUM UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring.
<br /> 80., D#' 44-024660 :y
<br /> -
<br /> UndergroundStorageTankPermitConditions -
<br /> 1) ,The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST systems)fails to remain in compliance with thew Permit Conditions.
<br /> 2) In order to maintain the operating permit,the owner and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCR,Title 23,Chap.16 and 18,as well as any conditions
<br /> established by San Joaquin County. 1
<br /> 3) If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the tank,the Permittee shall ensure that both.
<br /> the Tank Owner and tank Operator receive a copy of the permit.
<br /> 4) Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department(EHD)and are considererd UST Foram Conditions. The approved-
<br /> monitoring,response,and plot plans shall be maintained onsite with the permit.
<br /> 5) The Penni tec shall comply with the monitoring procedures referenced in this permit
<br /> 6) The Permittee shall perform testing.and preventive maintenance on all leak detection monitoring equipment annually;or more frequently if specified by the equipment manufacturer,and
<br /> provide documentation of such servicing to this office. - -
<br /> 7) In the event of a spill,leak,or other unauthorimd release,the Permitee shall comply with the requirements of Tide 23 CCR,Chap.16,Art.5,and the approved Emergency Response Plan.
<br /> 8) Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the date the monitoring was
<br /> performed
<br /> 9) The EHD shall be notified of any change in ownership or operation of the UST system within 30 days of such change. . .
<br /> 10) Upon any change in equipment,design or operation of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to review,modification or
<br /> revocation: -
<br /> 11) -Construction;repair and/or removal permits are required from the EHD prior to any change,repair or removal of UST system equipment.
<br /> 12) The Pennittee shall submit an annual report documenting compliance with the UST Permit Conditions within 30 days of thedate of the issuance of this permit
<br /> 13) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency.
<br /> 14) A"Conditional"Permit may be revoked if corrections specified on the inspection report are not completed by the dates) indicated.
<br /> PERMITS TO OPERATE are NOT TRANSFERABLE -
<br /> and may be SUSPENDED or REVOKED for cause.
<br /> PERMIT(s)Valid only for: ULTRAMAR INC
<br /> THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES
<br /> Regulated Facility: VALERO #3698 Facility ID-FA0003709
<br /> 153 E 11TH ST AccountlD AR0003288
<br /> TRACY CA 95376 Issued 2120/2007
<br /> Billing Address: ATTN : LICENSE & ,PERMITS
<br /> VALERO #3698 ' -
<br /> 685 W 3RD ST
<br /> HANFORD CA 93230
<br /> 7023.rpt
<br />
|