My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
7717
>
2300 - Underground Storage Tank Program
>
PR0231870
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2020 3:04:05 PM
Creation date
11/4/2018 4:57:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231870
PE
2361
FACILITY_ID
FA0003953
FACILITY_NAME
AT&T California - UE148
STREET_NUMBER
7717
STREET_NAME
ELM
STREET_TYPE
St
City
French Camp
Zip
95231
CURRENT_STATUS
02
SITE_LOCATION
7717 Elm St
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELM\7717\PR0231870\COMPLIANCE INFO 1986-2002.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ZNTTAIT Environmental Systems <br />General Contractors - CA Lic 9588098 <br />U.S.T. & A.S.T. MONITOR CERTIFICATION FORM <br />Testing Date: 8/5/99 <br />Site Location: PACIFIC BELL Tank ID(s): 1171 <br />907 LINCOLN ROAD CLLC Code: SKTNCAI 1 <br />STOCKTON Geo Parcel: UE -0A6 <br />County: SAN JOAQUIN Site Contact KEN MCDONALD <br />Site Contact Phone #: (209) 9A3-4128 <br />Make & Model of Monitor System($): VEEDER-ROOT TLS -350 <br />tDIESEL <br />Tank 2 =3Tank <br />Tank ID # <br />Type of Tank: (Single Wall or Double Wall) UST or AST <br />Contents of Tank: Capacity of Tank: Type of Product Line: (Gravity, Suction, Pressure) N <br />Type of Piping: (Single Wall or Double Wall) DW <br />INDICATE THE SENSORS TESTED BY PLACING A YES, NO, OR N/A & PASS OR FAIL IN <br />CORRESPONDING BOX: <br />Annular Space Sensor. <br />Fill Sump Sensor. <br />Piping Sump Sensor. <br />Piping Trench Sensor. <br />Dispenser Containment Sensor. <br />Problems System($) <br />Tank 1 Tank 2 Tank 3 Tank A Sensor -Type <br />YES MA55 <br />YES YES <br />FOR PRESSURE TYPE SYSTEMS ONLY: <br />Tank 1 Tank 2 Tank 3 Tank A <br />Is Mechanical Line Leak Detector Present & Tested?: <br />Does the Turbine Shut -Down if System Detects a Leak?: <br />Does Positive Shut Down Occur if Monitor System is fumed off?: <br />Is Tank Level Gauging System Present. Probe Type if Applicable. —MAG <br />GPH DAILY <br />Type of In -Tank Leak Detectir: on Test Performed by Monitor. <br />Does the Monitoring System have Audible &visual Alarms? YES <br />Electronic Overfill/Level: <br />Is the Monitoring System installed to prevent unauthorized tampering?: YES <br />Is the Monitoring Devices operable as per manufacture's specifications? YES <br />Date: 8/5/99 Technician: BRANDON HAM <br />(Priame) LI _ <br />Certified Tester's ID #: 39.3A35 111 <br />(Signature) <br />701 North Parkcenter Drive • Santa Ana, California 92705 • (714) 560-8222 (714) 560-8237 fax <br />Regional Offices: San Diego • Concord • Sacramento • Phoenix Tucson <br />w .TAIT.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.