My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON
>
1329
>
2300 - Underground Storage Tank Program
>
PR0231487
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2020 3:45:43 PM
Creation date
11/4/2018 5:09:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231487
PE
2351
FACILITY_ID
FA0000293
FACILITY_NAME
Pershing Holdings, Inc. DBA Esclon Arco
STREET_NUMBER
1329
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22510003
CURRENT_STATUS
01
SITE_LOCATION
1329 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ESCALON\1329\PR0231487\COMPLIANCE INFO 2018 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2018 - PRESENT
QuestysRecordDate
2/23/2018 11:34:59 PM
QuestysRecordID
3806209
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue , Stockton , California 95205 -6232 <br /> Telephone: (209 ) 468 -3420 Fax : (209 ) 468 -3433 Web: www. sj oq v . org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> ARCO 83812 1329 S ESCALON AVE , ESCALON February 15 , 2018 <br /> UST System Observations <br /> 321 CCR 2635(b) (2) Overfill prevention was overridden ❑ V ❑ R ❑ COS <br /> 322 HSC 25281 . 6 (a) Unburied below grade emergency generator system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 323 HSC 25283 . 5 (a) Unburied below grade UST system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 324 CCR 2717 . 1 (g ) Tampered with red tag ❑ V ❑ R ❑ COS <br /> 325 CCR 2717A (f) Deposited petroleum into a red tagged UST ❑ V ❑ R ❑ COS <br /> 326 HSC 25299(a) (9) Tampered with or disabled leak detection devices or alarms ❑ V ❑ R ❑ COS <br /> 327 CCR 2631 . 1 UST system not compatible with the substance stored ❑ V ❑ R ❑ COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑ V ❑ R ❑ COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements ❑ V ❑ R ❑ COS <br /> 330 CCR 2636 (f) (6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑ V ❑ R ❑ COS <br /> 331 CCR 2630 (d) Secondarily contained piping not maintained to allow liquid to drain into sump ❑ V ❑ R ❑ COS <br /> 332 CCR 2631 (b) , 2631 (d) Primary and/or secondary containment not constructed in accordance with the established standards ❑ V ❑ R ❑ COS <br /> Single -Walled Non -Pressurized Piping <br /> 401 CCR 2636(a) (3) Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R ❑ COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe (pre-Jan 1984) not performed ❑ V ❑ R ❑ COS <br /> 403 CCR 2643(d ) Triennial 0 . 1 gph line test for conventional suction piping not performed (pre-January 1984) ❑ V ❑ R ❑ COS <br /> 404 CCR 2643(e) Biennial 0 . 1 gph test for gravity piping not performed (pre-January 1984) ❑ V ❑ R ❑ COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I , CLASS II , or MINOR - Notice to Comply) <br /> Item # Remarks <br /> Overall Inspection Comments : <br /> FINAL INSPECTION FOR THE UST INSTALLATION ( UNDER SR0074800 ) . All field inspections have been <br /> completed . <br /> The following items must be submitted to EHD prior to receiving a permit to operate : <br /> • A written statement in the UST Monitoring Plan noting that UDC brine levels will be verified visually at least <br /> once a month and the inspection will be documented on site , due to the inability to view the brine levels through <br /> the metal brine reservoir . <br /> • Payment of all fees , including operating permit and service request/inspection fees . A copy of the most recent <br /> billing invoice can be obtained by calling the accounting office at (209 ) 468- 3447 . <br /> • A written statement from the UDC manufacturer (Western Fiberglass) approving the repair work that was <br /> done . ( For additional information regarding this work , please see the pre -approval letter issued by Western <br /> Fiberglass on 1 / 11 / 18 . ) <br /> • A " Certification of Installation/Modification " form for each tank submitted in CERS ( cers . calepa . ca . gov) , once <br /> the system installation is complete . <br /> FA0000293 PR0231487 SCO01 02/15/2018 <br /> EHD 23-01 Rev. 09/22/16 Page 3 of 4 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.