Laserfiche WebLink
San Joaquin County <br /> p <br /> Environmental Health Department o?- " '-•• c DIRECTOR <br /> �. .a <br /> �.' ,,..���, •G Donna Heran, REHS <br /> 600 East Main Street <br /> Stockton, California 95202-3029 PROGRAM COORDINATORS <br /> = Robert McCleHon, REHS <br /> Jeff Carruesco, REHS, RDI <br /> C�R r i�o'R r' P Website: www.sjgov.org/ehd KasLindy Fo k, REHS <br /> REHS <br /> Phone: (209) 468-342{? <br /> 1-10-11 Fax: (209) 464-0138 <br /> Denise Guzman <br /> Elite IV Contractors <br /> 2535 Wigwam Dr. <br /> Stockton, CA 95205 <br /> Re: George's BP Mini Mart 18662 E. Hwy 88 Lockeford, CA 95237 SR0061732 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of <br /> the application for a permit to install an OPW 71 SO drop tube on the 87 underground storage <br /> tank (UST) system at the above noted address. The permit has been approved with the <br /> following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Aris Cacapit at (209) 468-3453 to arrange the following inspection appointments <br /> (a 48-hour notice is required for inspection appointments). Please be aware that <br /> inspections for emergency work must be scheduled within five days of permit approval. <br /> a. Overfill prevention verification: Measurement of drop tubes to verify 95% tank volume <br /> shut off <br /> b. Spill bucket test: Verify minimum 5-gallon capacity and pass a one hour hydrostatic <br /> test (or equivalent). Proper drainage must also be verified. <br /> Please be aware that the facility cannot receive fuel in the 87 tank prior to the EHD <br /> inspection and approval. <br /> 4. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all of the <br /> following: <br /> a. One of several permissible valid, current contractor's licenses issued by the <br /> Contractors State License Board (may be issued to the installation company), or a <br /> Tank Tester's license issued to the individual by the State Water Board, and <br /> b. A valid, current California UST Service Technician certificate issued by the <br /> International Code Council (ICG), and <br /> c. A valid, current certificate of training from the manufacturer(s) of the component(s) <br /> being tested, repaired, or serviced. <br />