Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ONVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209) 468-3420 Fax: (209)468-3433 Web; www.slgov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> George's Bp Mini Mart 5/11/2010 <br /> Facility address: UST#1 1 2 3 <br /> 186+62 N. Hwy 88 Lockeford, Ca 95237 Product DIESEL 89 91 <br /> Facility contact: Title: Phone: 4 <br /> Ruppi Padda Owner 209 727-5028 87 <br /> Monitoring panel: Piping system: Overfill prevention: Violations: <br /> E Pressurized L] Suction ❑ Gravity ® Mechanical M1-RDetect ❑ M3-Both <br /> G I l ba rco ❑Audible/visual ❑ M2-RPrev <br /> Inspection type: Designated operator: ICC exp.date: <br /> Z Routine ® Monitoring Certification ❑ Installation ❑ Other ,Alex Jabbari 9/27/2010 <br /> On site Service Technician's name: ICC exp.date: Manufacturer's training: <br /> Zane Nimmo 6120/2011 Veeder Root Sept., 2011 & Vrni 2-8-11 <br /> # Code Section _ VIOLATIONS V R <br /> HSC=CA Health & Safety Code; CCR=CA Code of Regulations;V=Violation; RV=Re eat Violation V <br /> 1 HSC 25284 No permit to operate <br /> Secondary containment: (a)test not performed; (e)test report not submitted within 30 days; (f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department (EHD)at least 48 hours prior to <br /> conducting the test <br /> 3 CCR 2711(b)& (c) Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 CCR 2632(b) Monitoring Program (Monitoring & Response Plans)is not current or approved by the END <br /> 6 CCR 2712(i) Monitoring and/or response plan is not onsite <br /> Maintenance& monitoring records not maintained 3 years, cathodic protection records for 6 1z (M1) <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3) results <br /> I of any visual observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations, or other test results; (6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction piping (pre-January 1, 198 4)not performed (Mi) <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br /> 10 CCR 2632(c)(2) Monitorings stem is not present in the interstitial space of a double walled LIST/piping (Mi) <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(Mi) x <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (Mi) x <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping & UDCs that activates iMi) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631(a) Primary containment is not product tight <br /> 15 HSG 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br /> 17 CCR 2636(f)(2) Line leak detectors)not installed or failed to detect a 3-gallon per hour leak at 10 psi (Mi) <br /> 18 CCR 2635(b)(1) Spill container not installed,failed to contain a minimum capacity of five gallons,or failed to (M2) <br /> provide a means to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (Mz) <br /> 20 CCR 2636(a) Failed to have secondary containment for piping (includes conventional suction piping) (M2) <br /> 21 HSC 25291(e) Water in 2`containment not removed, analyzed $ properly disposed of <br /> Unauthorized release that: (c)did not escape secondary containment and cleaned up within eight (Mi) <br /> 22 CCR 2650 hours was not recorded; (e)escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b CCR 2715(b) Designated operator did not possess a current ICC UST System Operator certification <br /> Received b Title: <br /> EHD insA,,,, <br /> Y�- & <br /> EHE 23-02-002 REV 04108/10 Page 1 UST OFFICIAL INSPECTION REPORT <br />