BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 3:29:25 PM
Creation date
11/5/2018 9:26:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\BILLING 2013-2015.PDF
QuestysFileName
BILLING 2013-2015
QuestysRecordDate
7/5/2017 11:33:39 PM
QuestysRecordID
3483654
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
132
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6mtFIED PROGRAM CONSOLIDATED FOk!rW r <br /> TANKS ° h <br /> UNDERGROUND STORAGE TANKS - TANK PAGE <br /> _. (rwo Pam Pa's) <br /> aaaaaaaaa <br /> Page_of_ <br /> TYPE OF ACTION ® 1.NEW PERMIT ❑ 4.AMENDED PERMIT ❑ 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check ane item only) ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (specify reason) (Specify oaon) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(Same as FACILD'y14AME a DBA-wine Business As) 3. FACILITY ID: 1. <br /> Costco Gasoline Loc.No.0135 <br /> ATION WITHIN SIT (optional) <br /> a 631. <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432. TANK MANUFACTURER 433. COMPARTMENTALIZED TANK Yes No 434. <br /> 2 Containment Solutions If•wea^canplete ane pose far each campanaenr <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS <br /> (YEAR/MO) 437. <br /> 2002/05 20,000 1 <br /> ADDITIONAL DESCRIPTION(For foul use only) 438. <br /> Installation of 3-20,000 gallon underground gasoline storage tanks and associated product piping and monitoring systems. <br /> II.TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE <br /> 440 <br /> 19 1. MOTOR VEHICLE FUEL ® la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (IfcheckeQ canplate Penolemn Type) ❑ Ib. PREMIUM UNLEADED El 3. DIESEL 06. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (fian Harasdom Materials Invmto y page) 441- CAS#(gran Hazardous Materials inventory me) a42. <br /> ❑ 4. HAZARDOUS WASTE 87 Octane 8006-61-9 <br /> (Incmdea Mcd an <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL [13. SINGLE WALL WITH EXTERIOR [15. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL [14. SINGLE WALL IN A VAULT [199. OTHER <br /> TANK MATERIAL-primary tank 1. BARE STEEL 03. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95.UNKNOWN aha. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> TANK MATERIAL-secondary tank 1. BARE STEEL N3. FIBERGLASS/PLASTIC ❑8. FRP COMPTBLE W/100%METHANOL 95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> [15. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING 5.GLASS LINING ❑95.UNKNOWN 466. DATE INSTALLED 4Q. <br /> OR COATING ❑2.ALKYD LINING [14.PHENOLIC LINING ®6.UNLINED ❑99.OTHER <br /> (Check one item only) <br /> OTHER CORROSION ❑I.MANUFACTURED CATHODIC ®3.FIBERGLASS REINFORCED PLASTIC 0 95.UNKNOWN Me, DATE INSTALLED 449. <br /> PROTECTION PROTECTION [14.IMPRESSED CURRENT ❑99.OTHER <br /> (If Applicable) ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEARINSTALLED 450. TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) ®1.SPILL CONTAINMENT _2002 ® I.ALARM _2002 ❑3.FILL TUBE SHUT OFF VALVE <br /> ®2.DROP TUBE _2002 ®2.BALL FLOAT_2002 ❑4.EXEMPT <br /> ®3.STRIKER PLATE _2002_ <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑ 1. VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ®2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION ❑S.TANK TESTING <br /> (SIR),BIENNIAL TANK TESTING [3 99. OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456, TANK FILLED WITH INERT MATERIAL? 411. <br /> gallons []Yes ❑ No <br /> UPCF hwfwre-b(1/99)-1/4 http://www.unidoes.org Rev.02/16/00 <br />