My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FIRST
>
1116
>
2300 - Underground Storage Tank Program
>
PR0231100
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2021 2:19:49 PM
Creation date
11/5/2018 9:41:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231100
PE
2381
FACILITY_ID
FA0003700
FACILITY_NAME
CITY OF STOCKTON FIRE STATION #3
STREET_NUMBER
1116
Direction
E
STREET_NAME
FIRST
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16903006
CURRENT_STATUS
02
SITE_LOCATION
1116 E FIRST ST
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FIRST\1116\PR0231100\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/2/2013 8:00:00 AM
QuestysRecordID
152294
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A i c Vr VALIrUKN1A WATER RESOURCES CONTROL BOARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM (az TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK I C <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ d AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED O 7 <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: ���6 �' r • �_! Ln <br /> r-�.>� '>' '/</`� FARM TANK-YES❑ NO © N <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY �I <br /> A. OWNERS TANK IDM B. MANUFACTURED BY <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: S� <br /> II. TANK CONTENTS IF(AL1),IS MARKED,COMPLETE ITEM C.IF(AL1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑2 PETROLEUM B. C. ❑ I UNLEADED ❑ 2 LEADED 3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑ 1 OIL Q/PROOUCT ❑ A GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW( <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED 6 C.A.S.N C.A.S.X' <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,a D <br /> A TYPE OF ❑ I DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR UNEP ❑95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑1 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑TANK 1 STEEL/IRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑ 7 STEEL CLAD wIRBERGLAM REINFORCED PLASTIC <br /> B.MATERIAL ❑S CONCRETE ❑6 POLYVINYL CNLORIOE ❑ I ALUMNUM ❑B 100%METHANOL COMPATIBLE RIP <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> C.INTERIOR ❑ I RUBBER LINED ❑2 ALKYD LINING ❑3 EPDXYUNING ❑1 RU40 CLINING <br /> LINING ❑ 5 GLASS LINING ❑8 UNUNED F-195 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL] ❑YES ❑ NO ❑99 OTHER <br /> D.CORROSION ❑ 1 P(Xmm-BIEWRAP ❑2 TM OI ASPHALT ❑3 WNYLWMP F-11 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND.BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U I STEEL/IRON A U 2 STAINLESS STEEL A U3 POLYVINYL CHLORIDE(P/C) A U A FIBERGLASS PIPE A U 91 NONE <br /> C MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U T STEELCLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 8 1 VISUAL CHECK P ! 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P ! A ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P ! 6 PRECISION TESTING P 8 7 PRESSURE TESTING P ! 91 NONE P B 95 UNKNOWN P ! 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESi1MATE0 DATE UST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLON! INERT MATERIAL? E]YES ❑NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED A SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> 3JURISDICTION <br /> � AOE� FACILITY ID! � � TANK ID! <br /> CURRENT LOCAL AGENCY FACILITY 10 A APPROVED BY NAM! PHONE P WITH AREA COO! <br /> EN 64NO3 Y <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> 7 CHECK A PERMIT AMOUNT SURCHARGE AMT. FE[COD! RECEIPT I !T: <br /> �,� fORM R(9 29 A81 THIS FORM MUST BE ACCOMPANIED L _�ILITYISITE APPLICATION, FORM 'A',UNLESS A CG..WPFr FORM W HAS BEEERf <br /> ___ _ DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.