Laserfiche WebLink
CI <br /> /t2. <br /> IED PROGRAM CONSOLIDATED FOI`/ 1-7 it <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION- TANK INFORMATION (one tinrm per UST) <br /> TYPE OF ACTION (Check one item only. For a UST closure or removal,complete only this section and Sections 1,II,II(IV,and IX below) 430. <br /> ❑ I.NEW PERMIT ❑ 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 43. 1 DATE EXISTING UST DISCOVERED: 430b. <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) 11 <br /> BUSINESSNAME(Same as Facility Name or DBA-Doing Business As) 3. <br /> FLAG CITY ARCO/SUBWAY <br /> BUSINESS SITE ADDRESS 103 1 CITY 104. <br /> 14931 NORTH FLAG CITY BLVD. LODI, CA 95242 <br /> II. TANK DESCRIPTION <br /> TANKID# 432. TANK MANUFACTURER 433. TANK CONFIGURATION:THIS TANK IS 434. <br /> TA0506222 ❑ 1ASTAND-ALONE TANK Completeonepageforcteh <br /> ❑ 2.ONE INA COMPARTMENTED UNIT wmPentuou in the unit. <br /> DATE UST SYSTEM INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS M THE UNIT 437_ <br /> 4/1/1997 20,000 <br /> III. TANK USE AND CONTENTS <br /> TANK USE [0 la.MOTOR VEHICLE FUELING ❑ IF MARINA FUFLING ❑ Ic.AVIATION FUELING 439_ <br /> ❑ 3.CHEMICAL PRODUCISTORAGE ❑ 4_HAZARDOUS WASTE(Includes u.ed oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§252815(e)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 439.. <br /> .._______ _._. .......... _11-b- __ ......... <br /> CONTENTS PETROLEUM: ® Ia.REGULAR UNLEADED ❑ Ic MIDGRADE UNLEADED ❑ Ib PREMIUM UNLEADED 440. <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM(Specify): 440a. <br /> ------ <br /> .-__ _______ <br /> NON-PETROLEUM 0 7.USEDED OIL ❑ 10 ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM(Specify): 44W. <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 95.UNKNOWN 443_ <br /> PRIMARY CONTAINMENT ❑ I.STEEL ® 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444- <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN [1199.OTHER(Specify): 444a. <br /> SECONDARY CONTAINMENT ❑ .STEEL ®3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445 <br /> [1 90.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify): 445+. <br /> OVERFILL PREVENTION ❑ L AUDIBLE&VISUAL ALARMS ❑ 2 BALL FL1.OAT ® 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 99.OTHER 460. <br /> _._-.-.... .-...-- .... ________ ___-._-._ ... . ......... ..-.......- ......---" __..._....-._...-......-_ <br /> SYSTEM TYPE ® I.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[v CCR$2636(aAA] 458 <br /> PRIMARY CONTAINMENT ❑ ISTEEL ® 4 FIBERGLASS ❑ S.FLEXIBLE [310.RIGID PLASTIC 464. <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify). 464+ <br /> .... ......... ........._ <br /> SECONDARY CONTAINMENT ❑ I STEEL ® 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 4646 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 4Wa <br /> PIPINGFFURBINE CONTAINMENT SUMP TYPE ❑ 1 SINGLE WALL ® 2.DOUBLE WALL ❑ 90.NONE 464n_ <br /> VI. VENT, VAPOR RECOVERY (VR) AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ [I 9 <br /> 90.NONE 9.OTHER(Specify): d46e( <br /> VENT SECONDARY CONTAINMENT ❑ 1 STEEL ® 4 FIBERGLASS ❑ 10.RIGIDPLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464A, <br /> _ - ..-.-.- _45a. <br /> VR PRIMARY CONTAINMENT ❑ I STEEL ® 4 FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90 NONE ❑ 99.OTHER(Specify) 4�e <br /> ....-.-.- ....................... ...--- <br /> VR SECONDARY CONTAINMENT ❑ I.S1ELL EI 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 464hh' <br /> ____..__ -...-....- _i54i. <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 90NONE <br /> ________ .................. <br /> RISER PRIMARY CONTAINMENT ❑ I STEEL ® 4 FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) <br /> ._.___..-. .............1. _--1'-.- <br /> RISER SECONDARY CONTAINMENT ❑ 1.STEEL ® 4 FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 4�L <br /> FILL COMPONENTS INSTALLED ❑ 1 SPILL BUCKET ❑ 3 STRIKER PLATE/BOTTOM PROTECTOR ❑ 4.CONTAINMENT SUMP 451+-c. <br /> VII. UNDER DISPENSER CONTAINMENT (UDC) <br /> CONSTRUCTION TYPE ❑ I.SINGLF WALL ® 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE 469+- <br /> _.. ___. ______ -.-.-.-.- ................ .-.......... _._.__ <br /> CONSTRUCTION MATERIAL EI I.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC [0199.OTHER(Specify) 46% <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6_ISOLATION 448. <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: 1 certify a thi stem is compatible with the hazardous substance stored and that the information provided herein is true, <br /> accurst , i ul c liance with legal requirements. <br /> APPLICANT SIGNATURE DATE 6/25/2010 470, <br /> APPLICANT NAME(print) I HALLOUM 471, APPLICANT TITLE OWNER 472. <br /> UPCF UST-B Rev.(12/2007)-1/2 wiew.unidocs.org <br />