My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREDERICK
>
23073
>
2300 - Underground Storage Tank Program
>
PR0504047
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2021 10:31:21 PM
Creation date
11/5/2018 9:51:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0504047
PE
2381
FACILITY_ID
FA0006059
FACILITY_NAME
GICO MANAGEMENT
STREET_NUMBER
23073
Direction
S
STREET_NAME
FREDERICK
STREET_TYPE
Rd
City
Ripon
Zip
95366
APN
22813021
CURRENT_STATUS
02
SITE_LOCATION
23073 S Frederick Rd
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FREDERICK\23073\PR0504047\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/2/2013 8:00:00 AM
QuestysRecordID
152651
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD <br /> FORM `B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEWPERMIT ❑3 RENEWALPERMIT ❑ 5 CHANGEOFINFORMATION ❑�-�-�/7 PERMANENTLY CLOSED TANK 10 <br /> ONE ITEM ❑ 2 INTERIMPERMIT F-14 AMENDEOPERMIT ❑ 6 TEMPORARY TANK CLOSURE T TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 2�3 p Lnr� f. 1 ON FARM TANK-YES❑ NO N <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY C) <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: N <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑2 PETROLEUM B. C. ❑ 1 UNLEADED ❑2 LEADED ❑3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑4 OIL ❑ 1 PRODUCT ❑4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑95 UNKNOWN ❑2 WASTE ❑7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A. TYPE OF ❑1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑2 SINGLEWAUM ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ 1 STEELARON ❑2 STAINIESSSTEEL ❑3 FIBERGLASS ❑4 STEEL CUD W/FIBERGLA55 REINFORCED PLASTIC <br /> S. TANK ❑5 CONCRETE ❑ <br /> MATERIAL 6 POLYVINYLCHLORIDE F-17 ALUMINUM ❑8 10D%MMMOLCOMPATIBLEFRP <br /> ❑9 BRONZE ❑10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR ❑ 1 RUBBER UNED ❑2 ALKYD LINING ❑3 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS UNING ❑6 UNLINED ❑95 UNKNOWN <br /> ❑ IS UNING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑NO ❑99 OTHER <br /> D. CORROSION ❑ I POLYETHLENE WRAP ❑2 TAR OR ASPHALT ❑3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE ❑ 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IFABOVEGROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSMEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> d C. MATERIAL A U5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLADW/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> 6 1VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 8 3VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P 8 6 PRECISIONTESTING P 6 7 PRESSURE TESTING P 8 91 NONE P S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN 011LLON8 INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRIMED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> 2 6 sI I I IJ <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE N WITH AREA CODE <br /> iC R3 / 31 90 <br /> PERMITNUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK N PERYIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT BY: <br /> FORM B(6-29-68) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA HAS BEEN FILED <br />
The URL can be used to link to this page
Your browser does not support the video tag.