Laserfiche WebLink
30'-6" CONTAJNM ENT <br /> _ 6'-II 71T 7- 5X 10'-6 5/8- 7'-1 3 8" 3'-5 /4" COLLAR CONTAINMENT <br /> 46' 59 JIB' 16; 16 3/4' 46" 16 1/2" �� COLLAR <br /> r <br /> 41 7/8" " 6" , <br /> 1 MODERN WELDING <br /> OOR <br /> o •'+ _ _._._._._. ._._._.-__ FLUID CONTAINMENT Eo <br /> XERxES 'ol '✓b cc a_, -MODEL DWT TYPE II_ JACKETED STEEL <br /> FIBERGLASS FIBERGLASS III PLASTEEL <br /> 4....... <br /> CONTAINMENT <br /> 24 8" 12" 24'1 16 12" 24"� <br /> ,{ <br /> COLLAR CONTAINMENT c <br /> USE AINM ES SYSTEM IT 2T-8" 24" m C � m <br /> CONTAINMENT SUMP <br /> COLLAR 20'-3-1/2" <br /> 8"I f �1Jt <br /> L la <br /> I O <br /> 21 '-5 1/4" CONTAINMENT OOW <br /> )20 _8 1/4- CONTAINMENT <br /> 4'-I' 6 -2 I 4' COLLAR U 1 <br /> 4 -2COLLAR NN <br /> 16 1/2' <br /> �I <br /> WELDING JOOR 0 ¢ W 0.0 0 <br /> -- Q '-'----'--- O----'-ft v h ---------- _—---- V <br /> ,p JACKETED m .� - Od C <. <br /> STEEL ELUTRON E C G L U <br /> r - - - ---- —� r- CA♦m1 O <br /> CONTAINMENT <br /> xERxES CONTAINMENT 24!" 8" 12" 24' 16" 24"I <br /> rF 12" <br /> COLLAR FLUID CONTAINMENT }i O d' <br /> 'F24* <br /> FIBERGLASS MODEL DWT TYPE II COLLAR 10 19 -11-1/2 � > m � <br /> (SLOPE TO SENSOR) 000 Gallon Tank Fitting Orientation Details (SLOPE TO SENSOR) r Ae .08 C G� <br /> (SLOPE i0 SENSOR) 1 c <br /> NOT TO SCALE (SLOPE i0 SENSOR) 0 <br /> Material List at Tank SEE NOTE BELOW Material List at Dispenser Island SEE NOTE BELOW General Notes a. m r: <br /> _ � <br /> TEM DESCRIPTION POMECO OPW EMCO WHEATON UNIVERSAL CNI ITEM DESCRIPTION POMECO I DPW lEMC0 WHEATON UNIVERSAL CNI O o O <br /> 01 10,000 GAL. DOUBLE WALL 1. THE UNDERGROUND TANK SHALL BE A UNDERWRITER LABORATORIES INCORPORATED W) <br /> PRODUCT DISPENSERS <br /> MANF. TANK LISTED FOR THE UNDERGROUND STORAGE OF ALL FLAMMABLE AND COMBUSTIBLE X <br /> 48" TURBINE & 42" FILL BY TANK O TOKHEIM 262-VC-1 -RC-TWIN (SINGLE PRODUCT QUAL) 262-VC-2-RC-TWIN TWO PRODUCT DUAL <br /> TANK 26 (SCHLUMBERGER 613-2-R-AV (SINGLE PRODUCT DUAL) 612-2-R-AV (TWO PRODUCT DUAL) MOTOR FUELS. USTING MUST INCLUDE THE ABIUTY TO WITHSTAND A VACUUM TEST �Ix O <br /> DPWOF 13.8 INCHES OF HG. -4+ m <br /> O SIDE CONTAINMENT SUMPS BY TANK O NOT MODEL N 11 TAT OR EMCO WHEATONNOZZLES <br /> MODEL 4015 2. UNDERGROUND TANK INSTALLATION AND TESTING SHALL BE PER LL L. LISTED m O <br /> MANF. 27 COAXIAL DISPENSER NOZZLE NOTE: USE ONLY STATE APPROVED NOZZLES IN ALL LOCATIONS <br /> (SEE DET. 71 DWG. TK3-1) 'MANUFACTURER'S INSTALLATION INSTRUCTIONS". INSTALLATION SHALL CONFORM TO <br /> O <br /> COLLAR AT SUMP BY TANK <br /> NFPA-30 AND ALL APPLICABLE LOCAL AND STATE REGULATIONS. n.3 28 COAXIAL FUEL HOSE <br /> MANF. Q GOODYEAR "MAXXIM" 12.5' LENGTH, DAYCO 12.5' LENGTH 3. MONITOR SYSTEMS FOR THE INTERSTICE SHALL BE: BY A API/RONAN UQUID SENSOR, <br /> AND IN ACCORDANCE WITH APPLICABLE LOCAL AND STATE REGULATIONS. <br /> O36" Du. MANHOLE 110-36WT 78-3610 704.5 PHIL-TITE 29 RED JACKET 7 884-022-5 4. BEDDING AND BACKFILL MAY BE SAND, PFA GRAVEL, ROUNDED AGGREGATE CRUSHED <br /> RAINTIGHT 7 SC-3600-L OVERHEAD RETRACTOR CNI MODEL 7 9930-GYAK W/ GOODYEAR HOSE CLAMP ANTI KINK STONE OR NATIVE SOIL IN ACCORDANCE WITH MANUFACTURER'S CURRENT INSTALLATION <br /> INSTRUCTIONS AND ARCO SPECIFICATION 17800. <br /> S. THE DESIGN, ASSEMBLY, AND TESTING OF THE PIPING SYSTEM SHALL BE IN CONFORMANCE <br /> 5 4xx4AxTX2" FlTTING 233VM A79-023 Va21-2020 120-FM 340 EBWPRODUCTJ0 DOUBLE TPIMPACT VALVE 10-BPS A60 521OP-RM-15 EBW WITH THE APPLICABLE SECTION OF ANSI-831, AMERICAN NATIONAL STANDARD CODE <br /> 662-440-02 FOR PRESSURE PIPING, AND NFPA 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE. <br /> ORAIN COLLAR CAP BY TANK 31 VAPOR RECOVERY 60VSP 6. ALL ASSOCIATED PIPING SHALL BE PROTECTED FROM CORROSION, <br /> Y J <br /> MANF. IMPACT VALVE (SIDE ENTRY) 7. SEE DRAWINGS FOR NUMBER OF FITTINGS, CONFIGURATION, ACCESSORIES AND SUMP _ <br /> RISER DETAILS. I <br /> O b <br /> 7 EBW TITEFLEX U.L LISTED 7110165-24-0240, TELEFLEX U.L. LISTED 760-t0a73-0240 <br /> m <br /> FLOATvaLv 53VML A75-004 37-201216 123-12C 308-207-01 32 1-1/2" FLEX CONNECTOR 24" ANAMET U.L LISTED 7107627-1000 m � <br /> HOSEMAS7ER U.L. LISTED # TCM51.5-24 W/ACSWA (TEFLON) <br /> HOSEMASTER U.L. LISTED CC <br /> O TURBINE RED JACKET MODEL 7 P150S1 OR � AGPISOSI 7 FSMS1.5-24 W/ACSWA (STAINLESS) Abbreviations List <br /> PUMP 1.5 H.P. F.E. PETRO MODEL STP-V-150 SECONDARY CONTAINMENT FLEX TITEFLEX 7 111466-42, TELEFLEX 7 60-10498-0240 W/ 760-10459, 4 () <br /> 33 <br /> LEAK (MECHANICAL) RED JACKET MODEL 7116035-5 (PISTON TYPE), 711fi0J6-5 (DIAPHRAGM TYPE) SECTION UNDER DISPENSER AUSTIN ENGINEERING 7336-FP4 (FOR ANAMET), CONTAINMENT TECHNOLOGIES v <br /> O <br /> DETECTOR F.E. PETRO MODEL 7STP-MLD (PISTON TYPE), VAPORLESS MODEL TLD-2000 UNDER DISPENSER SPILL "TOTAL CONTAINMENT' MODEL OP2416 "AMERICAN CONTAINMENT' MODEL AC-DD-ARCO ABBR. DESCRIPTION ABBR. DESCRIPTION • <br /> Ja CONTAINMENT SUMP "WESTERN FIBERGLASS", MODEL 1120-51 (SINGLE FRP) 1120-52' (DUAL FRP , <br /> "WESTERN FIBERCLAS5' 1122P-51 (SINGLE HDPE), 1122P-S2 (DUAL HDPE), �ENVI ROH" A.C. ASPHALT CONCRETE MNPT MALE NATIONAL PIPE THREADS m Q Fr <br /> TITEFtEX U.L. LISTED 7110165-32-0240, TELEFLEX U.L. LISTED 760-10477-0240 API AMERICAN PETROLEUM INSTITUTE N.C. NORMALLY CLOSED °' U <br /> O 2" x 24" L FLEX CONNECTOR / 7 822962-4000 (STAINLESS) O UNDER DISPENSER SUMP 'VEEDER ROOT MODEL 7 847-990-001 W/ MOUNTING BRACKET, BEAUDREAU MODEL 7404-4 APPROX. APPROXIMATE NIP NIPPLE m Z Z <br /> ANAMET U.L. LISTED 7 107547-1000 W <br /> 10 W/SWIVEL END ( 35 MONITORING PROBE LATCHING CONTROLLER AND SENSOR, 'UNIVERSAL" PROBE MODEL 7 DIS-01 <br /> HOSEMASTER U.L. LISTED # TCMS2.0-24 W/ACSWA (TEFLON) (IF USED) "API/RONAN' MODEL 7 LS-6AUX. AUXILIARY G Q/� (ry u < <br /> HOSEMASTER U.L. LISTED 7 FSMS2.0-24 W/ACSWA (STAINLESS) NPT NATIONAL PIPE THREAD <br /> UNDER DISPENSER SUMP BLU. BLUE N0. NUMBER C <br /> 6c z <br /> W J <br /> 036 PRODUCT PIPING PENETRATION "TOTAL CONTAINMENT" MODEL 7FB0030, "ENVIRON" SEB-3520 BLK. BLACK N.C. NORMALLY OPEN i LL i L- ,n <br /> II TING a. m <br /> J"%2' TEST REDUCER TCI 7TR3200 FIT <br /> WEAVER N3X2-A UNDER DISPENSER SUMP C. CONDUIT N/A N07 APPLICABLE '^ <br /> FER CO 37 VAPOR PIPING PENETRATION "TOTAL CONTAINMENT" MODEL 7FBV030, "ENVIRON' SEB-1015 COMB. COM81NATION N.T.S. NOT TO SCALE <br /> 18' DIA INSPECTION FITTING CONN. CONNECTOR/CONNECTION 0.D. OUTSIDE DIAMETER <br /> 12 <br /> WELL MANHOLE (WATERTIGHT) 110-18WT 98MW-1810 7029 UNDER DISPENSER SUMP CORP. CORPORATION P PRODUCT LINE <br /> 38 <br /> INSPECTION WELL PIPE - 4" HYDROPHILIC CONDUIT PENETRATION FITTING TOTAL CONTAINMENT MODEL 7UB1075, "ENVIROW CEB-3075 q CENTER LINE PVC POLYVINYL CHLORIDE <br /> FITTING <br /> A 13 SCHEDULE 40 14' LONG 7650 ++ DBL. DOUBLE OTY. OUANTITY t„j <br /> . qj <br /> 020' SLITS FACTORY CUT OR EQUAL <br /> 'POMECO" 7 511C-16, "CNF 36-05, 'PHIL-TITE SC-3600-TSC-2 J9 D DEEP REF. REFERENCE <br /> O36' DIA, MANHOLE WITH 2- 7 7 DIM. DIMENSION REO'0. REQUIRED <br /> 14 5 GALLON CONTAINMENT SUMPS 1N OREGON & WASHINGTON FOR COAXIAL FILL USE 15' #SCO" MODEL 7511D-16. WHEN 4w ( '6'0 <br /> 15 GAL. SPILL CONTAINMENT REQ'0. USE: "PHIL-TITE' 75C-3600-TSC-2 W/ 15 GAL. D.C. DIRECT CURRENT RSG RIGID STEEL GALVANIZED � �. <br /> 15 FILL ADAPTER & CAP N/A 633-T-8075 A30-014 724_4040 EBW WA & OR Material List at Building SEE NOTE BELOW DWG. DRAWING SPECS. SPECIFICATIONS '- <br /> 778-100-01 EMCO WT.-01 A97-005 EMT ELECTRICAL METALLIC TUBING SCH. SCHEDULE <br /> 634-TT-7085 A97-005 733-40 777-202-01 COAXIIA0) ITEM DESCRIPTION w (� <br /> ELL ELBOW SCR'O. SCREWED ca •; LN <br /> 16 VAPOR CHECK VALVE 1611 -AV-1620 A76-005 611V-3040 611-08-4A EBW OPW MODEL 7 5235, UNIVERSAL MODEL 7 46CS, CNI MODEL 7126 FT. FOOT SEC SECTION <br /> & CAP N/A W/1711-T-7085 A99-002 614VC-30 611 -VTR-3 300-300-01 • 40 VENT CAP EBW MODEL 7800, EMCO WHEATON MODEL 7A84 im m c <br /> 304-301-01 INSTALLED ONLY IF REQUIRED BY AGENCY HAVING LOCAL JURISDICTION FLEX. FLEXIBLE TY,P, TYPICAL ^ `, m� <br /> OWA & OR FRP FIBERGLASS REINFORCED PLASTIC U.L. UNDERWRITERS LABORATORY E .� V <br /> 17 OVERFILL PREVENTION 61-SO AAIIGO- 01 EBW DPW 61 -SOP 41 FNPT FEMALE NATIONAL PIPE THREAD U/G UNDERGROUND <br /> DROP TUBE A1100-001 708-410 LEAK DETECTION MONITOR RONAN SERIES X765 (SEE DWG. TK4-1) <br /> (COAXIAL) F.G. FIBERGLASS V VAPOR LINE CL Q <br /> t8 LIQUID LEAK SENSOR API/RONAN GAL, GALLON VAC VOLT AMP CURRENT Er" <br /> A7 SUMP 7 LS-3 42 INTERFACE BOX TOKHEIM MODEL 67/67A (SEE DWG. TTC4-1) GALV. GALVANIZED V.R. VAPOR RECOVERY <br /> HEY HEXAGON VIC. VIOLET <br /> 19 LIQUID LEAK SENSOR API S-7 EMERGENCY CUT-OFF SWITCH SQUARE 0 CLASS 39001 K25 FLUSH PLATE PUSHBUTTON WITH K60 COVER, INDOOR H.P. HORSEPOWER WHIT. WHITE <br /> a3 J <br /> FOR TANK ANNULAR SPACE 7 LS-7 (INDOOR) (SEE DWG. TK4-1) 1.0. INSIDE DIAMETER W/ WITHC O O <br /> SECONDARY J-BOX JUNCTION BOX <br /> (METHANOL COMPATIBLE) , <br /> �+ <br /> - 20 CONTAINMENT PIPING EITHER A.O. SMITH 'RED THREAD IIA", AMERON DUALOY '3000/L", O TOKHEIM MODEL 168/268 <br /> 4a RELAY CONTROL BOX V' <br /> OR CONTAINMENT TECHNOLOGIES AS DIRECTED (SEE DWG. TK4-1) L LONG <br /> MAX. MAXIMUM <br /> .� 21 PRIMARY EITHER A.O. SMITH "RED THREAD IA", AMERON DUALOY 3000/L, <br /> CONTAINMENT PIPING 45 AUXILIARY RELAYS RONAN INTRINSICALLY SAFE RELAYS MODEL 7 KV-700-NO-24 MANF. MANUFACTURER c. <br /> OR CONTAINMENT TECHNOLOGIES AS DIRECTED (METHANOL COMPATIBLE) O (SEE DWG. TK4-1) MIN. MINIMUM � C O <br /> 2T" "TOTAL CONTAINMENT" J' CB3050, 2" CB2030, "ENVIRON" 3" FEB-6300 2' FEB-6200 71956 <br /> BULKHEAD FITTING q6 EMERGENCY CUT-OFF RELAY SQUARED MODEL 7X040-VO2, 1WIT COIL, RE Hz, UT AMP CONTACTS, 4-POLE N.O. IN THIS DRAWING USED IN RETANKING REPIPING PROJECTS aPPr. <br /> SUMP PENETRATION ASSEMBLY CLASS 9991 NEMA 1 ENCLOSURE WITH N.O. RESET BUTTON (SEE DWG. TKa-1) WHEN EXISTING BUILDING IS TO REMAIN. K.J. MCCORMACK <br /> 2J COMPRESSION FITTING, "TOTAL CONTAINMENT' U81075, "ENVIRON' FEB-3075 8x8x4 HOFFMAN ENCLOSURE, NEMA 1. SCREW COVER DATE R E V 18 I O N 8 date drawn by <br /> AIRTIGHT 47 JUNCTION BOX <br /> (SEE DWG. TK4-1) 7/12/94 SHK <br /> A ISSUED FOR PLAN CHECK <br /> 24 2" BALL VALVE APOLLO O EMERGENCY CUT-OFF SWITCH SQUARE 0 CLASS 9001 KR3RH6 PUSHBUTTON N.C. WITH K60 COVER IN WEATHERPROOF project 7fcallty <br /> ' (OUTDOOR) ENCLOSURE (SEE DWG. TK4-1) <br /> CONTRACTOR SUPPUED, OTHER . THIS ITEM IS OPTIONAL DEPENDING NOTE: THIS MATERIALS EQUIPMENT SCHEDULE IS NOT A COMPLETE LIST OF MATERIALS. sheet / Ole <br /> ITEMS SUPPUED BY ARCO UNLESS ON LOCAL JURISDICTION REQUIREMENTS CONTRACTOR S RESPOIOE8LE FOR ALLETE AND OPERABLE EQUIPMENT, MATERIALS T'�4-3 <br /> NOTED OTHERWISE, AND DEVICES 11L` <br /> B of <br />